Î

Use spray lance with pressure regula-
tion (Vario Power).
Turn the spray lance to "Mix" position.

Î

Check the settings at the dosage regu-
lator for detergent.

Î

Check the detergent suction hose for 
kinks.

Australia

KÄRCHER Pty. Ltd.
40 Koornang Road
Scoresby, Victoria 3179

1800 675 714 (Free Call)
www.karcher.com.au

Subject to technical modifications!

No detergent infeed

Customer Service

Technical specifications

Electrical connection

Voltage

230-240

1~50

V
Hz

Connected load

2,2 kW

Protection class

IP X5

Protective class

I

Mains fuse (slow-blow)

16 A

Water connection

Max. feed pressure

0,6 MPa

Max. feed temperature

60 °C

Min. feed volume

11 I/min

Max. Suction height

1,0 m

Performance data

Working pressure

13 MPa

Max. permissible pressure

15 MPa

Water flow rate

8,2 I/min

Detergent flow rate

0,3 I/min

Recoil force of trigger gun

20 N

Dimensions and weights

Length

407 mm

Width

447 mm

Height

972 mm

Weight 19,8 kg

Summary of Contents for K 6.450

Page 1: ...R egister and w in w w w kaercher com Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them K 6 450 59639200 10 10 ...

Page 2: ...be recycled Please arrange for the proper recycling of old appliances Please dispose your old appli ances using appropriate collection sys tems Notes about the ingredients REACH You will find current information about the ingredients at http www karcher de de unternehmen umweltschutz REACH htm The scope of delivery of your appliance is il lustrated on the packaging Check the con tents of the appli...

Page 3: ...rank for hose drum 10 Storage of detergent reservoir with de tergent connection 11 Storage for accessories 12 Storage hook for mains connection cable 13 Mains cable with mains plug 14 Detergent reservoir with locking lid 15 Wheels 16 Trigger gun 17 Lock trigger gun 18 Key to detach the high pressure hose from the trigger gun 19 Washing brush 20 Spray lance with Dirtblaster 21 Spray lance with pres...

Page 4: ...f explosion Do not spray flammable liquids Never draw in fluids containing solvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable explosive and poi sonous Do not use acetone undiluted acids and solvents as they are damag ing to the materials from which the ap pliance is made 몇 Warning The mains plug and the c...

Page 5: ...ng operations which produce oily waste water e g engine washes un derbody washes may only be carried out using washing stations equipped with an oil separator This appliance was designed to be used with detergents which are sup plied or recommended by the manufac turer The use of other detergents or chemicals may compromise the safety of the appliance Caution Safety devices protect the user and mu...

Page 6: ...e drinking water supply without a system separator Use a suitable system separator manufactured by KÄRCHER or as an alternative a system separator as per EN 12729 Type BA Water flowing through a system separator is con sidered non drinkable Caution Always connect the system separator to the water supply never directly to the appli ance Note Impurities in the water can damage the high pressure pump...

Page 7: ...n Î Unwind the high pressure hose from the hose drum Hold on to the transport handle during this procedure Note If the hand crank is in its secured position fold it up first Î Completely open the water tap Î Completely uncoil the mains cable Î Insert the mains plug into the socket Î Turn on the appliance I ON 몇 Danger The trigger gun is subjected to a recoil force when the water jet is discharged ...

Page 8: ...ustration Î Adjust the suction volume of the deter gent solution by means of the dosage regulator for detergents Î Use spray lance with pressure regula tion Vario Power Î Turn the spray lance to Mix position Note This will mix the detergent with the water stream Note If required the washing brushes can be used to work with detergent Î Spray the detergent sparingly on the dry surface and allow it t...

Page 9: ...n with the spray lance into the holder for the hand spray gun Illustration Î Stow away the mains cable the high pressure hose and accessory at the ap pliance Prior to extended storage periods as dur ing the winter also observe the instructions in the Care section Caution Protect the appliance and its accessories against frost The appliance and its accessories can get destroyed through frost if the...

Page 10: ...he trigger gun the device will switch on Î Check whether the voltage indicated on the type plate corresponds to the volt age of the mains supply Î Check the mains connection cable for damages Î Check setting at the spray lance Î Appliance ventilation Switch on the appliance without con nection the high pressure hose max 2 minutes and run it until the water dis charging from the high pressure outle...

Page 11: ...detergent infeed Customer Service Technical specifications Electrical connection Voltage 230 240 1 50 V Hz Connected load 2 2 kW Protection class IP X5 Protective class I Mains fuse slow blow 16 A Water connection Max feed pressure 0 6 MPa Max feed temperature 60 C Min feed volume 11 I min Max Suction height 1 0 m Performance data Working pressure 13 MPa Max permissible pressure 15 MPa Water flow ...

Page 12: ...12 English Assembly ...

Page 13: ...English 13 Assembly ...

Page 14: ...14 English Notes ...

Page 15: ...English 15 Spare Parts ...

Page 16: ......

Reviews: