background image

12 

English

CAUTION

Risk of personal injury or damage! 
Mind the weight of the appliance during transport.

Lift appliance by the carrying handle and carry it.

Pull out the transport handle until it audibly snaps 
into place.
Pull the appliance by its transport handle.

Prior to horizontal transport: Remove the Plug 'n' 
Clean detergent bottle from the intake and close it 
with the lid.

Secure the appliance against shifting and tipping 
over.

CAUTION

Risk of personal injury or damage! 
Consider the weight of the appliance when storing it.

Park the machine on an even surface.

Detach spray lance from the trigger gun.

Push the disconnect button on the trigger gun and 
pull the high-pressure hose out of the trigger gun.

Place the trigger gun into the storage for the trigger 
gun.

Put both spray lances into the storage for the spray 
lance.

Dirtblaster spray lance: Nozzle towards the bottom.

Vario Power spray lance: Nozzle towards the top.

Store the mains connection in the accessory com-
partment.

CAUTION

Risk of personal injury or damage! 
Observe the rotation direction of the hose reel upon coil-
ing up the high-pressure hose.

Coil up the high-pressure hose.
Turn the hose reel in a 

counter-clockwise direc-

tion

 using the crank handle.

Prior to extended storage periods, as during the winter, 
also observe the instructions in the Care section.

ATTENTION

Appliances and accessories that are not completely 
drained can be destroyed by frost. Completely drain ap-
pliance and accessories and protect them against frost.

To avoid damage:

Detach the appliance from the water supply.

Detach spray lance from the trigger gun.

Turn on the appliance “I/ON”.

Push the lever of the trigger gun until no more wa-
ter is escaping (approx. 1 min).

Release the lever of the trigger gun.

Lock the lever of the trigger gun.

Turn off the appliance "0/OFF".

Store the appliance and the entire accessories in a 
frost free room.

DANGER

Risk of electric shock.

Prior to all work on the appliance, switch off the ap-
pliance and pull the power plug.

The high pressure hose is specially constructed with re-
inforced walls to handle water pressure up to 13 MPa 
(1900 psi) - it can be easily damaged and should be 
stored carefully.

Do not kink.

Do not drive vehicles over the hose.

Do not expose the hose to sharp edges or corners.

Misuse will lead to ballooning or premature failure and 
will invalidate warranty.

Clean the sieve in the water connection regularly.

Remove coupling from the water connection.

ATTENTION

The sieve must not be damaged.

Illustration 

Pull the sieve out using flat pliers.

Clean the sieve under running water.

Reinsert the sieve into the water connection.

The batteries are depleted if nothing is shown on the 
display of the trigger gun anymore.
Two batteries or accumulators of the size AAA are re-
quired.
Illustration 

Push the locking slide.

Open battery compartment.

Remove the batteries.

Insert new batteries and observe the correct orien-
tation of the terminals.

Close battery compartment.

Dispose of the used batteries according to the local 
provisions.

Transport

When transporting by hand

When transporting in vehicles

Storage

Storing the Appliance

Frost protection

Care and maintenance

High pressure hose

Clean the sieve in the water connection

Changing the batteries of the trigger gun

Summary of Contents for K 5 Premium

Page 1: ...K 5 Premium Full Control Operating Instructions Please read the operating instructions carefully before using the unit 59677640 05 17...

Page 2: ...iption of the Appliance 8 Proper use 9 Environmental protection 9 Assembly 10 Start up 10 Operation 11 Transport 12 Storage 12 Care and maintenance 12 Troubleshooting 13 Warranty 13 Technical specific...

Page 3: ...plug and the socket with wet hands Check the power cord with mains plug for damage prior to every use Immediately have damaged power cord replaced by an authorised customer service electrician Do not...

Page 4: ...um DANGER The user must use the appli ance as intended The person must consider the local condi tions and must pay attention to other persons in the vicinity when working with the appli ance Check imp...

Page 5: ...ity for the appli ance prior to any work on or with the appliance to prevent accidents or damage The water jet that is emitted from the high pressure nozzle results in a repulsion power acting on the...

Page 6: ...arator Ensure that the connection of your building water installation on which the high pressure cleaner is operated is equipped with a system separator pursuant to EN 12729 Type BA Water that has flo...

Page 7: ...sure cleaners aerosols can develop Inhaling aerosols can cause health damage Depending on the applica tion completely shielded noz zles e g surface cleaner that significantly reduce the emission of a...

Page 8: ...8 English Description of the Appliance...

Page 9: ...s buildings tools facades terraces gardening tools etc by means of a high pressure water jet if necessary with ad ditional cleaning agents with accessories replacement parts and cleaning agents approv...

Page 10: ...recommended Observe regulations of water supplier ATTENTION Hose couplings made of metal with aquastop can dam age the pump Please use plastic couplings or K RCH ER brass couplings Illustration Screw...

Page 11: ...he cap of the Plug n Clean detergent bottle Illustration Push the detergent bottle with the opening pointing downwards into the connection for the Plug n Clean detergent Use Vario Power spray lance Tu...

Page 12: ...e appliance from the water supply Detach spray lance from the trigger gun Turn on the appliance I ON Push the lever of the trigger gun until no more wa ter is escaping approx 1 min Release the lever o...

Page 13: ...bubbles Switch off appliance and reconnect HP hose Clean high pressure nozzle Remove dirt and de bris from the nozzle bore using a needle and rinse through with water from the front Check water flow q...

Page 14: ...ter connection Max feed pressure 1 2 MPa Max feed temperature 40 C Min feed volume 10 l min Max Suction height 0 5 m Performance data Working pressure 12 MPa Max permissible pressure 14 5 MPa 2100 psi...

Page 15: ...English 15 Illustration...