background image

English

 7

Warning

According to the applicable regula-
tions, the appliance must never be 
used on the drinking water supply 
without a system separator. Use a 
suitable system separator manufactured by 
KÄRCHER; or, as an alternative, a system 
separator as per EN 12729 Type BA. Water 
flowing through a system separator is con-
sidered non-drinkable. 

Caution

Always connect the system separator to the 
water supply, never directly to the appliance!

Observe regulations of water supplier.
For connection values, see type plate/tech-
nical data.

Caution

Hose couplings made of metal with aquas-
top can damage the pump! Please use 
plastic couplings or KÄRCHER brass cou-
plings.

Use a fibre-reinforced water hose (not 
included) with a standard coupling. 
(Minimum diameter 1/2 inch (13 mm), 
minimum length 7.5 m).

Illustration 
Screw the coupling element to the wa-
ter connection on the appliance.

Push the water supply hose onto the 
coupling unit.

Connect the water supply hose to the 
water supply.

Completely open the water tap.

Note:

 Impurities in the water can damage 

the high-pressure pump and accessories. 
For protection, the use of the KÄRCHER 
water filter (optional accessory, order no. 
4.730-059) is recommended.

Note:

 The max. suction height is 0.5 m.

Fill the suction hose with water.

Illustration 
Screw the suction hose into the water 
connection of the appliance and insert it 
into the water source (e.g. rainwater 
drum).

Caution

Dry runs lasting longer than two minutes 
lead to damages to the high pressure 
pump. If the appliance does not build up 
pressure within two minutes, switch it off 
and proceed as instructed in the Chapter 
"Troubleshooting".

Completely uncoil the mains cable.

Insert the mains plug into the socket. 

Set the appliance switch to "1/ON".

Illustration 
Unwind the high pressure hose from the 
hose drum. Hold on to the transport 
handle during this procedure.

Note

: If the hand crank is in its secured 

position, fold it up first.

Unlock the lever on the trigger gun.

Pull on the lever of the trigger gun; the 
device will switch on.
Switch the appliance on for a (max. of 2 
minutes) and wait until the water exits at 
the hand spray gun without bubbles.

Release the lever on the trigger gun.

Set the appliance switch to "0/OFF“.

Caution

Prior to cleaning, make sure that the high 
pressure is placed safely on level ground. 
Wear protective goggles and protective 
clothing during the cleaning process.

Illustration 
Push the spray lance into the trigger 
gun and fasten it by turning it through 
90°.

Set the appliance switch to "1/ON".

Danger

The trigger gun is subjected to a recoil force 
when the water jet is discharged. Make 
sure that you have a firm footing and are 
also holding the trigger gun and spray lance 
firmly.

Pull on the lever of the trigger gun; the 
device will switch on.

Note:

 Release the lever of the trigger gun; 

the device will switch off again. High pres-
sure remains in the system.

Water supply

Water supply from mains

Drawing in water from open reservoirs

Start up

Operation

Summary of Contents for K 4 Premium ecologic

Page 1: ...Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them 59644820 01 12 K 5 800 eco ogic...

Page 2: ...ances using appropriate collection systems The extraction of water from public waters is prohibited in some countries Work with detergents must only be performed on liquid tight work surfac es with c...

Page 3: ...s containing solvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable explosive and poi sonous Do not use aceton...

Page 4: ...y the manufac turer The use of other detergents or chemicals may compromise the safety of the appliance The high pressure hose is specially con structed with reinforced walls to handle wa ter pressure...

Page 5: ...rage of Plug n Clean detergent bot tle with detergent connection 12 Storage for accessories 13 Storage hook for mains connection cable 14 Mains cable with mains plug 15 Plug n Clean detergent bottle w...

Page 6: ...ose drum Illustration Slide the free end of the coiled high pressure hose through the recesses on the dosage regulator Illustration Attach the transport handle insert the bolts into the bores and scre...

Page 7: ...rainwater drum Caution Dry runs lasting longer than two minutes lead to damages to the high pressure pump If the appliance does not build up pressure within two minutes switch it off and proceed as in...

Page 8: ...ter gent bottle into the detergent connec tion with the opening facing down Illustration Adjust the suction volume of the deter gent solution by means of the dosage regulator for detergents Use spray...

Page 9: ...un with the spray lance into the holder for the hand spray gun Illustration Stow away the mains cable the high pressure hose and accessory at the ap pliance Prior to extended storage periods as dur in...

Page 10: ...ut con nection the high pressure hose max 2 minutes and run it until the water dis charging from the high pressure outlet is free of bubbles Switch off appliance and reconnect high pressure hose Check...

Page 11: ...f charge provided that such failure is caused by faulty material or defects in man ufacturing In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service cen...

Page 12: ...ent Authorised Documentation Representative S Reiser Alfred K rcher GmbH Co KG Alfred K rcher Str 28 40 71364 Winnenden Germany Phone 49 7195 14 0 Fax 49 7195 14 2212 Winnenden 2011 10 01 EC Declarati...

Page 13: ...English 13 Assembly...

Page 14: ...14 English...

Page 15: ...English 15 Spare Parts...

Page 16: ......