background image

3

IMPORTANT PRECAUTIONS – 

Read First!

2

  

Safety Warnings

When using this product, basic precautions
should always be followed:

Read all the instructions before using the
product.

High pressure jets can be dangerous if
subject to misuse. The jet must not be
directed at persons, animals, electrical
devices, or the machine itself.

To reduce the risk of injury, do not
operate the machine near children.

Learn how to stop the machine and
release pressure quickly. Be thoroughly
familiar with the controls.

Stay alert — watch what you are doing.

Wear safety goggles.

Do not use acids, solvents,
or any flammable material in
this product. These products can cause
physical injuries to the operator and
irreversible damage to the machine.

Do not operate the product when fatigued
or under the influence of alcohol or drugs.

Keep operating area clear of all persons.

Do not stand on unstable surfaces.
Stand with both feet balanced at all
times.

To reduce the risk of electrocution, keep
all connections dry and off the ground.
Do not touch plug with wet hands.

The Trigger Gun Safety Lock PREVENTS
the trigger from accidentally being
engaged. This safety feature DOES NOT
lock trigger in the on position.

EXTENSION CORDS

Use a sufficient gauge: Up to 25 ft = 12/3
AWG; 25 to 50 ft = 10/3 AWG. Use only
extension cords that are intended for outdoor
use. These extension cords are identified by
the marking “Acceptable for use with outdoor
appliances; store indoors while not in use.”
Use only extension cords having an electrical
rating not less than the rating of the product.
Do not use damaged extension cords.
Examine extension cord before using and
replace if damaged. Do not abuse extension
cord and do not yank on any cord to
disconnect. Keep cord away from heat and
sharp edges. Always disconnect the extension
cord from the receptacle before disconnecting

the product from the extension cord. If you are
using an extension cord, it should always be
completely unwound from the cable drum.

GROUND FAULT CIRCUIT
INTERRUPTER (GFCI) PROTECTION

This product is supplied with a Ground Fault
Circuit Interrupter (GFCI) built into the power
cord plug. This device provides additional
protection from the risk of electric shock. If
power is interrupted in the line, the GFCI will
automatically re-close the circuit to the load
after power is restored. Depending on the
GFCI model, it may be necessary to manually
operate the reset button to restore power to
the GFCI load circuit. If replacement of the
plug or cord is needed use identical
replacement parts.

GROUNDING INSTRUCTIONS

This product must be grounded. If it should
malfunction or breakdown, grounding provides
a path of least resistance for electric current
to reduce the risk of electric shock. This
product is equipped with a cord having an
equipment-grounding conductor and a
grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed
and grounded in accordance with all local
codes and ordinances.
DANGER- Improper connection of the
equipment-grounding conductor can result in a
risk of electrocution. Check with a qualified
electrician or service personnel if you are in
doubt as to whether the outlet is properly
grounded. Do not modify the plug provided
with the product - if it will not fit the outlet,
have a proper outlet installed by a qualified
electrician. Do not use any type of adapter
with this produc

t.

 Caution

• Follow the maintenance instructions
specified in the manual.
• This machine has been designed for
use with cleaning detergent supplied or
recommended by the manufacturer. The
use of other cleaning detergents may
affect the operation of the machine and
void the warranty.

Summary of Contents for K 395 M

Page 1: ...own Clean Up 8 Taking a Break 8 Winterizing and Long Term Storage 8 Care and Maintenance Instructions 9 Cleaning Tips 9 10 Optional Cleaning Accessories 10 Troubleshooting 11 12 Specifications Operating pressure 1500 PSI Water volume 1 7 GPM Voltage 120 V Amp draw 14 AMPS In USA call 1 800 537 4129 or visit our website www karcher usa com Manual Part No 5 961 049 0 08 03 Part No 1 141 966 0 ...

Page 2: ...rgent filter suction tube 13 High pressure outlet 14 Water inlet 15 Package of 6 screws not pictured Never point nozzle at people or animals Never drink alcohol or use drugs while operating this equipment Never operate while standing in water Never touch plug with wet hands Never let electrical connections rest in water Never Never Never Never Never operate pressure washer without the water turned...

Page 3: ...y from heat and sharp edges Always disconnect the extension cord from the receptacle before disconnecting the product from the extension cord If you are using an extension cord it should always be completely unwound from the cable drum GROUND FAULT CIRCUIT INTERRUPTER GFCI PROTECTION This product is supplied with a Ground Fault Circuit Interrupter GFCI built into the power cord plug This device pr...

Page 4: ...F 40 C Never use the pressure washer to draw in water contaminated with solvents e g paint thinners gasoline oil etc Always prevent debris from being drawn into the unit by using a clean water source ASSEMBLY INSTRUCTIONS Step 2 Place detergent tank between adapter brackets as shown Attach second adapter bracket Step 3 Attach handle onto top of adapter brackets Press down to lock Tighten with scre...

Page 5: ...nect garden hose to unit s water inlet Step 4 Connect garden hose to the cold water source and turn water on completely Step 5 Plug the power cord into the power outlet Unlock the lock of the trigger gun Trigger the gun to eliminate trapped air wait for a steady flow of water to emerge from the spray nozzle Step 6 Turn on the pressure washer I The motor starts only if the trigger of the gun is pul...

Page 6: ...OR ANIMALS GFCI INSTRUCTIONS Step 1 Plug the Ground Fault Circuit Interrupter GFCI into a working outlet Step 2 If the GFCI light glows press the Test button until the light goes out Step 3 Press the Reset button to restore power to the washer USING THE ACCESSORIES The Vario spray wand allows you to adjust the cleaning pressure To clean at maximum pressure the Vario wand must be positioned to the ...

Page 7: ...ducts These chemicals will harm the unit and will damage the surface being cleaned Working with detergents Detergents can only be applied at low pressure The following Karcher detergents are available One Gallon ready to use Vehicle Wash Degreaser All Purpose Cleaner House Wash Deck Wash Detergent Concentrate Tablets 10 Pack makes 1 1 4 gallon RTU product All Purpose Degreaser Deck and patio Windo...

Page 8: ...Insert detergent suction tube into 1 gallon of fresh water Siphon water at low pressure for one minute Step 3 Turn the switch to off O position and unplug cord from outlet Turn off the water source Step 4 Press trigger to release water pressure Step 5 Disconnect the garden hose from the water inlet on the unit Step 2 Turn pressure washer to off O position WINTERIZING AND LONG TERM STORAGE TAKING A...

Page 9: ... rotating nozzle spray wand on siding as it may cause damage Cement Patios Brick and Stone with or without detergent Pre rinse cleaning surface with fresh water If using Karcher All Purpose Cleaner place detergent suction tube directly into cleaning solution and apply to surface at low pressure For best results limit your work area to smaller sections of approximately 25 square feet Allow Kärcher ...

Page 10: ...g solution and apply to surface at low pressure Allow Kärcher All Purpose Cleaner to remain on surface 1 3 minutes Do not allow detergent to dry on surface If needed use special Wash Brush Attachment to remove stubborn dirt Rinse at high pressure in a sweeping motion keeping the spray nozzle approximately 3 6 inches from the cleaning surface For best results clean from top to bottom and from left ...

Page 11: ...ged Discharge nozzle is obstructed Calcified gun hose or spray wand Solution Turn switch to the ON I position Plug in power cord Replace extension cord with either a 25 ft 12 3 gauge cord or a 50 ft 10 3 gauge cord Try a different outlet Reset breaker power supply or ground fault circuit interrupter Replace with a 3 4 inch garden hose Check garden hose for kinks leaks and blockage Open water sourc...

Page 12: ...d fittings are air tight Turn off machine and purge pump by squeezing trigger gun until a steady flow of water emerges through the nozzle Check that all fittings are tight Call service center Call service center Symptom No detergent Garden hose connection leaks Spray wand leaks Pump is noisy Water leaks from pump up to 10 drops per minute is permissible Oil Drip Cause Detergent suction tube not pr...

Reviews: