background image

English

According to the applicable regula-
tions, the appliance must never be 
used on the drinking water supply 
without a system separator. Use a 
suitable system separator manufactured by 
KÄRCHER; or, as an alternative, a system 
separator as per EN 12729 Type BA. Water 
flowing through a system separator is con-
sidered non-drinkable.

Observe regulations of water supplier.
For connection values, see type plate/tech-
nical data.

Î

Use a fibre-reinforced water hose (not 
included) with a standard coupling. 
(Minimum diameter 1/2 inch (13 mm), 
minimum length 7.5 m).

Î

Screw the coupling element (supplied) 
to the water connection on the appli-
ance.

Î

Push the water supply hose onto the 
coupling unit, then connect it to the wa-
ter supply.

This high-pressure cleaner is suited to work 
with the KÄRCHER suction hose with back-
flow valve (Optional accessory, order no. 
4.440-238) to draw in surface water, e.g. 
from water butts or ponds (see specifica-
tions for max. suction height). 

Î

Fill the KÄRCHER suction hose with 
backflow valve with water, screw to wa-
ter supply and hang into the water butt.

Î

Appliance ventilation: Switch the appli-
ance on with the high-pressure hose 
detached and operate (max. 2 minutes) 
until the water exits the high-pressure 
connection without bubbles. Switch off 
appliance and reconnect high-pressure 
hose.

Mount loose parts delivered with appliance 
prior to start-up.

Illustrations on Page 2

Illustration 

Î

Insert the transport wheels and lock them.

Illustration 

Î

Insert the transport handle and screw in.

Illustration 

Î

Push the high pressure hose into the 
trigger gun until it locks audibly.

Note:

 Make sure the connection nipple 

is aligned correctly.

Î

Check the secure connection by pulling 
on the high-pressure hose.

Caution

Dry runs lasting longer than two minutes 
lead to damages to the high pressure 
pump. If the appliance does not build up 
pressure within two minutes, switch it off 
and proceed as instructed in the Chapter 
"Troubleshooting".
In case of impurities in the supply water, a 
3/4" fine water filter must be used.

Î

Connect the high pressure hose to the 
high pressure connection of the appli-
ance.

Î

Push the spray lance into the trigger gun 
and fasten it by turning it through 90°.

Î

Completely open the water tap.

Î

Insert the mains plug into the socket. 

Î

Turn on the appliance “I/ON”.

Danger

The trigger gun is subjected to a recoil force 
when the water jet is discharged. Make sure 
that you have a firm footing and are also hold-
ing the trigger gun and spray lance firmly.

Î

Unlock the lever on the trigger gun.

Î

Pull on the lever of the trigger gun; the 
device will switch on.

Note:

 Release the lever of the trigger gun; 

the device will switch off again. High pres-
sure remains in the system.

Operation

Water supply

Water supply from mains

Drawing in water from open reservoirs

Before Startup

Start up

Operation

Summary of Contents for K 3.150

Page 1: ...Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them K 3 150 59635360 12 09...

Page 2: ...gun 8 Detergent Tank 9 Connection for water supply with filter 10 Mains cable with mains plug 11 Bearing wheel 12 Coupling element for water connection 13 Trigger gun 14 Key to detach the high pressur...

Page 3: ...be recycled Please arrange for the proper recycling of old appliances Please dispose your old appli ances using appropriate collection sys tems Notes about the ingredients REACH You will find current...

Page 4: ...lvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable explosive and poi sonous Do not use acetone undiluted aci...

Page 5: ...ing operations which produce oily waste water e g engine washes un derbody washes may only be carried out using washing stations equipped with an oil separator The high pressure hose is specially con...

Page 6: ...ose Mount loose parts delivered with appliance prior to start up Illustrations on Page 2 Illustration Insert the transport wheels and lock them Illustration Insert the transport handle and screw in Il...

Page 7: ...high pressure jet Release the lever on the trigger gun Lock the lever on the trigger gun During longer breaks more than 5 min utes also turn the appliance off using the 0 OFF switch Caution Only separ...

Page 8: ...er from the ap pliance Switch the appliance on with detached high pressure hose and de tached water supply max 1 minute and wait until no more water exits at the high pressure connection Turn off the...

Page 9: ...iance switch to I ON Clean high pressure nozzle Remove dirt and debris from the nozzle bore us ing a needle and rinse through with wa ter from the front Check water flow quantity Slight leakage from t...

Page 10: ...e 40 C Min feed volume 8 I min Max feed pressure 1 2 MPa Max Suction height 0 5 m Performance data Working pressure 10 MPa Max permissible pres sure 12 MPa Water flow rate 5 5 I min Detergent flow rat...

Page 11: ...English 11 Spare Parts...

Page 12: ......

Reviews: