background image

English

  9

We hereby declare that the machine de-
scribed below complies with the relevant 
basic safety and health requirements of the 
EU Directives, both in its basic design and 
construction as well as in the version put 
into circulation by us. This declaration shall 
cease to be valid if the machine is modified 
without our prior approval.

The undersigned act on behalf and under 
the power of attorney of the company man-
agement.

Alfred Kärcher GmbH Co. KG
Alfred Kärcher-Str. 28 - 40
D - 71364 Winnenden
Phone: +49 7195 14-0
Fax: +49 7195 14-2212

Technical specifications

Power connection 

Voltage (1~50 Hz)

220-240 V

Connected load

1,4 kW

Mains fuse (slow-blow)

10 A

Protective class

II

Protection class

IP X5

Water connection

Max. feed temperature

40 °C

Min. feed volume

8 I/min

Feed pressure,

0,2-1,2 MPa

Performance data

Working pressure

8 MPa

Max. permissible pressure

10 MPa

Water flow rate

5,5 I/min

Detergent flow rate

0,4 I/min

Recoil force of handgun

12 N

Hand-transmitted vibration 
(ISO 5349)

0,8 m/s

2

Sound pressure level 
Lpa (EN60704-1)

77 dB(A)

Sound power level 
Lwa (2000/14/EG)

91 dB(A)

Dimensions

Length

390 mm

Width

160 mm

Height

260 mm

Weight

4 kg

CE declaration

Product:

High-pressure cleaner

Type:

1.601-xxx

Relevant EU Directives

98/37/EC
2006/95/EC
2004/108/EC
2000/14/EC

Applied harmonized standards

EN 60335–1
EN 60335–2–79
EN 55014–1: 2006
EN 55014–2: 1997 + A1: 2001
EN 61000–3–2: 2000 + A2: 2005
EN 61000–3–3: 1995 + A1: 2001 + A2: 2005

Applied conformity evaluation method

Appendix V

Sound power level dB(A)

Measured:

90 dB(A)

Guaranteed: 91 dB(A)

CEO

Head of Approbation

Summary of Contents for K 2.19

Page 1: ...Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them K 2 19 5 961 753 0 11 07...

Page 2: ...2...

Page 3: ...tion systems The terms of the guarantee applicable in each country have been published by our respective national distributors We will re pair possible faults on your unit free of charge within the w...

Page 4: ...uted acids and solvents as they are aggres sive towards the materials from which the appliance is made Warning Check the high pressure hose for dam age before every use Please arrange for the immediat...

Page 5: ...To avoid accidents due to electrical faults we recommend the use of sock ets with a line side current limiting cir cuit breaker max 30 mA nominal tripping current The plug and coupling of the extensio...

Page 6: ...the trigger gun to release it and pull lever Risk of injury The trigger gun is subjected to a recoil force when the water jet is discharged Make sure that you have a firm footing and are also holding...

Page 7: ...t the mains plug Roll up the power cord and loop it e g round the handle Risk of frost Protect the appliance and accessories against frost The appliance and its accessories can get destroyed through f...

Page 8: ...to run until the water which discharges from the high pressure outlet is free of bubbles Then connect the high pres sure hose again Clean the filter in the water supply con nection This can be easily...

Page 9: ...tection class IP X5 Water connection Max feed temperature 40 C Min feed volume 8 I min Feed pressure 0 2 1 2 MPa Performance data Working pressure 8 MPa Max permissible pressure 10 MPa Water flow rate...

Page 10: ...our con sultants are unable to take all calls coming in In these circumstances we would ask that you try to contact us again later in the day The helpline number is 01295 752200 open from 8 30am to 5...

Page 11: ...11...

Page 12: ......

Reviews: