background image

English

 7

Caution

Dry runs lasting longer than two minutes 
lead to damages to the high pressure 
pump. If the appliance does not build up 
pressure within two minutes, switch it off 
and proceed as instructed in the Chapter 
"Troubleshooting".

Î

Connect the high pressure hose to the 
high pressure connection of the appli-
ance.

Î

Push the spray lance into the trigger 
gun and fasten it by turning it through 
90°.

Î

Completely open the water tap.

Î

Insert the mains plug into the socket. 

Î

Turn on the appliance “I/ON”.

Danger

The trigger gun is subjected to a recoil force 
when the water jet is discharged. Make 
sure that you have a firm footing and are 
also holding the trigger gun and spray lance 
firmly.

Î

Unlock the lever on the trigger gun.

Î

Pull on the lever of the trigger gun; the 
device will switch on.

Note:

 Release the lever of the trigger gun; 

the device will switch off again. High pres-
sure remains in the system.

For normal cleaning tasks.
Not suitable for use with detergents.

Please use exclusively KÄRCHER deter-
gents and care products to carry out the re-
spective cleaning task, as these were 
specifically developped for your appliance. 
The use of other detergents and care prod-
ucts may lead to premature wear and can 
invalidate your warranty claims. Please ob-
tain information at your local dealer or re-
quest information directly from KÄRCHER.

Î

Detach spray lance from the trigger 
gun. Work only with the trigger gun.

Î

Suspend end of detergent suction hose 
in a container filled with detergent.

Î

Spray the detergent sparingly on the 
dry surface and allow it to react, but not 
to dry.

Î

Spray off loosened dirt with the high-
pressure jet.

Î

Release the lever on the trigger gun.

Î

Lock the lever on the trigger gun.

Î

During longer breaks (more than 5 min-
utes), also turn the appliance off using 
the "0/OFF" switch.

Î

Insert the trigger gun in its holder.

Caution

Only separate the high-pressure hose from 
the trigger gun or the appliance while there 
is no pressure in the system.

Î

After working with detergent, suspend 
detergent suction hose in a container 
filled with clear water, switch the appli-
ance on for around 1 minute once the 
spray lance has been removed and 
rinse until water runs clear.

Î

Release the lever on the trigger gun.

Î

Turn off the appliance "0/OFF".

Î

Turn off tap.

Î

Detach the appliance from the water 
supply.

Î

Press the lever on the trigger gun to re-
lease any remaining pressure in the 
system.

Î

Lock the lever on the trigger gun.

Î

Pull out the mains plug.

Î

Stow away the mains cable, the high-
pressure hose and accessory at the ap-
pliance.

Start up

Operation

Spray lance with high pressure nozzle

Working with detergent

Recommended cleaning method

Interrupting operation

Finish operation

Summary of Contents for K 2.010

Page 1: ...R egister and w in w w w kaercher com English 3 Bahasa Indonesia 11 59638920 07 10 K 2 010...

Page 2: ...2...

Page 3: ...n umweltschutz REACH htm The warranty terms published by the rele vant sales company are applicable in each country We will repair potential failures of your appliance within the warranty period free...

Page 4: ...lvents or undiluted acids and solvents This in cludes petrol paint thinner and heating oil The spray mist thus generated is highly inflammable explosive and poi sonous Do not use acetone undiluted aci...

Page 5: ...pe plate on the appliance For safety reasons we recommend that you operate the appliance only via a earth leakage circuit breaker max 30 mA Cleaning operations which produce oily waste water e g engin...

Page 6: ...nect high pressure hose to trigger gun Push the clamp in until it locks Check the secure connection by pulling on the high pressure hose According to the applicable regula tions the appliance must nev...

Page 7: ...y claims Please ob tain information at your local dealer or re quest information directly from K RCHER Detach spray lance from the trigger gun Work only with the trigger gun Suspend end of detergent s...

Page 8: ...ace Insert the trigger gun in its holder Stow away the mains cable the high pressure hose and accessory at the ap pliance Caution Protect the appliance and its accessories against frost The appliance...

Page 9: ...e type plate corresponds to the volt age of the mains supply Check the mains connection cable for damages Appliance ventilation Switch the appli ance on with the high pressure hose de tached and opera...

Page 10: ...ctive class II Mains fuse slow blow 10 A Water connection Max feed temperature 40 C Min feed volume 8 I min Feed pressure 0 2 1 2 MPa Performance data Working pressure 8 MPa Max permissible pressure 1...

Page 11: ...archer de de unternehmen umweltschutz REACH htm Garansi yang kami berikan berlaku di setiap perusahaan penjualan yang resmi di setiap negara Kami memperbaiki ke rusakan perangkat Anda tanpa biaya sama...

Page 12: ...rotan ketika membersihkan Mudah meledak Jangan menyemprotkan ke cairan yang mudah terbakar Jangan menyedot cairan yang mengan dung bahan bahan seperti pelarut atau asam murni Termasuk mis bensin ti ne...

Page 13: ...boleh mengguna kan listrik pengganti yang sesuai Te gangan listrik harus sama dengan yang tercantum di perangkat Demi alasan keamanan sebaiknya pe rangkat Anda menggunakan sekring maks 30 mA dalam pe...

Page 14: ...gan menggunakan obeng kecil Gambar Pasang selang bertekanan tinggi di pi stol penyemprot Klip ditekan sampai klik Periksa sam bungan telah aman terpasang pada se lang bertekanan tinggi Menurut peratu...

Page 15: ...di bagian informasi Pisahkan pipa penyemprot dari pistol penyemprot Hanya gunakan pistol penyemprot Letakkan selang penyedot untuk cairan pembersih di dalam wadah dengan cai ran pembersih Semprotkan c...

Page 16: ...aan yang rata Letakkan pistol penyemprot di dalam tempat penyimpanannya Bongkar kabel steker selang berteka nan tinggi dan aksesoris dalam perang kat Hati hati Lindungi perangkat dan aksesoris dari ko...

Page 17: ...ol penyemprot perangkat akan menyala Periksa apakah tegangan yang ada se suai dengan tegangan yang tercantum dalam perangkat Periksa apakah kabel steker dalm kon disi rusak Biarkan perangkat mendapat...

Page 18: ...Derajat perlindungan IP X5 Tingkat perlindungan II Sekring utama lambat 10 A Sambungan air Temperatur masuk maks 40 C Jumlah masuk min 8 l min Tekanan masuk 0 2 1 2 MPa Data kinerja Tekanan pengopera...

Page 19: ...19...

Page 20: ...Dublin 12 01 409 77 77 KOR Karcher Co Ltd South Korea Youngjae B D 50 1 51 1 Sansoo dong Mapo ku Seoul 121 060 032 465 8000 MAL Karcher Cleaning Systems Sdn Bhd No 8 Jalan Serindit 2 Bandar Puchong J...

Reviews: