– 3
Illustration on the inside of the front
cover
Bring the device into the working posi-
tion.
Ensure that the container lid has been
fitted properly.
Lock clamping bracket (IVR-B 30/15 Me
only).
Illustration
Connect the suction hose to the suction
unit.
Insert the suction hose into the suction
hose connection.
Illustration on the inside of the front
cover
Insert the mains plug into the socket.
Illustration
Turning on the Appliance
Start suction process.
The motor protection switch interrupts the
electric circuit if the motor is overloaded.
Allow engine to cool down.
Check suction hose, container and ex-
haust air for clogging.
Switch the machine back on again.
If the motor circuit breaker trips again after
switch-on, stop the operation and inform
customer service.
Illustration on the inside of the front
cover
Switch off the appliance and remove
the plug from the socket.
Illustration
Unlock clamping bracket (IVR-B 30/15
Me only).
Remove the container lid and put it
aside.
Pull the suction hose off the suction
hose connection.
Remove the container from the base
plate and empty it.
Dispose of the contents according to
the local provisions.
Place the container on the base plate.
Insert the suction hose into the suction
hose connection.
Refit the container lid and check for
proper seating.
Lock clamping bracket (IVR-B 30/15 Me
only).
Empty the container
Remove deposits from the container.
Dispose of deposits in accordance with
the applicable regulations.
Note:
The container can be cleaned wet.
Allow the container to dry completely after
wet cleaning prior to using it again. Do not
use high-pressure cleaners for cleaning.
Switch off the appliance using the On/
Off switch.
Empty and clean the container.
Note:
Empty vacuum cleaner after every
use.
몇
CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
몇
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.
Start up
Operation
Turn it on.
1
Shut-off
0
Motor protection switch
Empty the container
Clean the container
Shutting down
Transport
Storage
11