26

HDS 995

7.2

Indicator lights

•••••

Indicator light for fuel tank lights up
– Refill with fuel.
– Check that the fuel level sensor is

functioning correctly.

•••••

Indicator light for engine-overheating lights
up
– Eliminate the cause of the overload.
– Allow the engine to cool down to room

temperature.

•••••

Indicator light for liquid softener lights up
– Refill with RM 110 liquid softener.
– Clean the electrodes in the liquid softener

tank.

7.3

The appliance does not come up to
pressure

•••••

Rotate the pressure and volume control to the
maximum value.

•••••

Fill the detergent tank or set the metering
valve to zero.

•••••

Vent the appliance (see Operation, chap. 5).

•••••

Clean the strainer in the water connection.

•••••

Check the water intake volume (see technical
data, chap. 3).

•••••

Check all the supply lines to the pump for
leaks and blockages.

7.4

The pump is knocking

Check all the supply lines to the pump, also
the detergent system, for leaks and blockages.

Vent the appliance (see Operation, chap. 5).

7.5

Detergent is not being drawn in

•••••

Let the appliance run with opened metering
valve (max. setting) and without high-pressure
hose, until the detergent visibly emerges at
the appliance outlet.

•••••

Clean the detergent suction hose and filter.

•••••

Clean the metering valve for cleaning agent.

•••••

Clean the non-return valve on the pump head
and the connection for the detergent suction
hose.

•••••

Check all the detergent hoses and
connections for leaks.

7.6

Burner does not ignite

•••••

The ignition sparks can be observed through
the inspection window in the burner cover.
The appliance has a continuous ignition., i.e.
even when operating with cold water an
ignition spark must be visible. Clean, adjust
or replace the ignition electrodes as required.
– Fill the fuel tank.
– Check that the fuel pump and the fuel

solenoid valve function correctly.

– Clean the strainer in the low-water safety

device.

– Change the fuel filter.

7.7

The temperature is not reached
when operating with hot water/steam

•••••

Set the thermostat higher.

•••••

Reduce the operating pressure and the flow
rate.

7. Troubleshooting

Summary of Contents for HDS995

Page 1: ...5 951 736 07 99 HDS995 www karcher com...

Page 2: ...la seguridad para limpiadoras de alta presi n De bedes l se denne driftsvejledning igennem f r idrifttagningen i denne forbindelse skal is r Sikkerhedsforskrifter for h jtryksrenser overholdes F r ibr...

Page 3: ...3 HDS 995...

Page 4: ...ce for fuel 2 Handle 3 Instrument panel 4 View window with maintenance fault display 5 Reset button 6 Compartment for accessories 7 Short time operating instructions 8 Cover flap for filling orifices...

Page 5: ...70 bar Flow rate 470 1000 l h 470 1000 l h Operating temperature max 140 C 80 C 140 C 80 C Detergent intake 0 50 l h 0 50 l h Burner capacity 76 kW 76 kW Recoil force of hand held spray gun at operati...

Page 6: ...The liquid softener prevents the heating element from becoming calcified when operating with hard supply water The liquid softener is added in drops to the supply water in the water tank The metering...

Page 7: ...the burner First position the appliance switch to STOP and then put the electric plug into the socket If you are using an extension lead it should alwaysbecompletelyunwoundfromthecable drum and have a...

Page 8: ...romback spray Always ensure that all connecting hoses are securely screwed on The gun trigger must not be clamped when operating the appliance The exhaust opening must not be blocked Do not bend over...

Page 9: ...for light dirt max 60 C for dirt which contains protein e g in the food industry 60 90 C for cleaning vehicles machines Switch the appliance switch to If you also increase the operating pressure and f...

Page 10: ...e jet When you have finished working with detergent you should set the detergent metering valve to 0 and rinse the appliance thoroughly with the gun open for approx 1 minute 5 8 Interrupting operation...

Page 11: ...work has been carried out you should press the reset buttonnexttothedisplayforatleast7seconds until the warning light goes out 7 S 8 S 9 S 6 s Display Required Maintenance Work Optical inspection Che...

Page 12: ...nment When the oil has completely drained screw the oil drain plug back in and slowly pour in oil up to the MAX position on the oil tank air bubbles must escape See technical data chapter 3 for quanti...

Page 13: ...e correctedthefaultandswitchedtheappliance back on 1 F 7 Troubleshooting Display Corrective Action Increase water supply volume Clean strainer in water connection Clean strainer before the low water s...

Page 14: ...ages Vent the appliance see Operation chap 5 7 5 Detergent is not being drawn in Let the appliance run with opened metering valve max setting andwithouthigh pressure hose until the detergent visibly e...

Page 15: ...ir the function of the appliance and are dangerous It is advisable to use K rcher accessories which are made to order Your dealer will be glad to advise you 8 3 Spare parts Please note that the use of...

Page 16: ...4 0 5 321 378 0 6 313 014 0 5 321 377 0 5 063 447 0 5 363 290 0 5 731 039 0 5 337 021 0 5 321 379 0 5 392 017 0 5 321 403 0 7 312 004 0 7 306 049 0 5 305 204 0 4 775 196 0 2 884 085 0 2 880 296 0 6 36...

Reviews: