Unit Function
HDS Middle Range / HDS Premium Range
Page 32 / 127
Service Manual 04.2008
2.11 Cleaning agent tank 2
Suction hose with filter (removed)
Level sensor, cleaning agent tank 2 (removed)
1
4
Cleaning agent tank 2 (right-hand side)
3
1
5
6
1
2
Cleaning agent tank 2
The cleaning agent tank 2 (1) is located in the
right-hand part of the chassis.
Suction hose
The retaining plug with suction hose (3)
connection is located above the right-hand
transport wheel. A cleaning agent filter (4) is fitted
onto the end of the suction hose.
Level sensor (optional)
The level sensor (5) contains a reed switch which
is actuated by means of a magnet in the float (6).
3
1 Cleaning agent tank 2
2 Cap, cleaning agent tank 2
3 Screw plug with suction hose connection,
cleaning agent tank 2
4 Cleaning agent filter
5 Level sensor, cleaning agent tank 2
(optional)
6 Float with magnet, level sensor