– 5
DANGER
Risk of explosion!
Do not spray flammable liquids.
DANGER
Risk of injury! Never use the appliance
without the spray lance attached. Check
and ensure proper fitting of the spray lance
prior to each use. The screw connection of
the spray lance must be fingertight.
몇
WARNING
Long hours of using the appliance can
cause circulation problems in the hands on
account of vibrations.
It is not possible to specify a generally valid
operation time, since this depends on sev-
eral factors:
– Proneness to blood circulation deficien-
cies (cold, numb fingers).
– Low ambient temperature. Wear warm
gloves to protect hands.
– A firm grip impedes blood circulation.
– Continuous operation is worse than an
operation interrupted by pauses.
In case of regular, long-term operation of
the device and in case of repeated occur-
rence of the symptoms (e.g. cold, numb fin-
gers) please consult a physician.
Note:
With especially hard water, calcium
can be flocculated at a higher rate inside
the boiler. This is a natural phenomenon
and it does not impact the function of the
appliance, so long as the maintenance in-
tervals are adhered to (see "Care and
Maintenance").
DANGER
Switch the appliance off prior to replacing
nozzle and activate hand spray gun until
device is pressureless.
1 Operating with cold water
2 Eco! efficiency setting (hot water max.
140 °F/60 °C)
3 Operating with hot water
Set appliance switch to desired operat-
ing mode.
Indicator lamp for operational readiness
lights up.
The device starts briefly and turns off, as
soon as the working pressure is reached.
Note:
If the indicator lamps for pump, lack
of water, boiler malfunction or motor, turn
off the appliance immediately and repair
malfunction, refer to "Help with malfunc-
tions".
Release the trigger gun.
When activating the hand spray gun the de-
vice switches back on.
Note:
If no water comes out of the high
pressure nozzle, vent pump. Refer to "Help
with malfunctions - appliance is not building
up pressure".
Set temperature regulator to desired
temperature.
86 °F/30 °C to 185 °F/85 °C:
– Clean with hot water.
Operation
Safety instructions
Boiler
Replace the nozzle
Operating modes
0/OFF = Off
Turning on the Appliance
Adjust cleaning temperature