background image

– 4

For connection values refer to technical specifications.

Connect the supply hose (minimum length 7.5 m, 
minimum diameter 3/4“) to the water connection of 
the unit and to the water inlet (e.g. tap) using the 
water connection adapter.

Note:

 The supply hose is not included in the scope of 

delivery.

If you want to suck in water from an external vessel, the 
following modification is necessary:

Figure 6

Open fill opening for system care.

Release and remove the cover of the system care.

Remove water connection from the fine filter.

Unscrew the fine filter from the pump head.

Figure 7

Remove the system care reservoir.

Unscrew the top supply hose to the swimmer con-
tainer.

Figure 8

Connect the top supply hose at pump head.

Replug the rinse line of the detergent dosing valve.

Connect suction hose (minimum diameter 3/4“) 
with filter (accessory) to the water connection point. 

Max. suck height: 0.5 m

Until the pump sucked in water, you should:

Set the pressure/quantity regulation at the pump 
unit to maximum quantity.

Close the dosing valve for the detergent.

DANGER

Risk of personal injury or damage! Never suck in water 
from a drinking water container. Never suck in liquids 
which contain solvents like lacquer thinner, petrol, oil or 
unfiltered water. The sealings within the device are not 
solvent resistant. The spray mist of solvents is highly in-
flammable, explosive and poisonous.

For connection values, see technical data and type 
plate.

The electrical connections must be done by an 
electrician according to IEC 60364-1. 

DANGER

Risk of injury on account of electric shock!

Unsuitable electrical extension cables can be haz-
ardous. Only use electrical extension cables out-
doors which have been approved and labelled for 
this purpose and have an adequate cable cross-
section.

Always unwind extension lines completely.

The plug and coupling of the extension cable used 
must be watertight.

ATTENTION

The highest allowed net impedance at the electrical 
connection point (refer to technical data) is not to be ex-
ceeded. In case of confusion regarding the power im-
pedance present on your connection, please contact 
your utilities provider.

DANGER

Danger of explosion! Do not spray flammable liquids.

DANGER

Risk of injury! Never use the appliance without the spray 
lance attached. Check and ensure proper fitting of the 
spray lance prior to each use. The screw connection of 
the spray lance must be finger-tight.

DANGER

Risk of injury! Hold the hand spray gun and the spray 
pipe firmly with both hands.

DANGER

Risk of injury! The trigger and safety lever may not be 
locked during the operation.

DANGER

Risk of injury! Contact Customer Service if the safety le-
ver is damaged.

ATTENTION

Risk of damage! Never operate device with an empty 
fuel tank. The fuel pump will otherwise be destroyed.

To open the trigger gun: Actuate the safety lever 
and trigger.

To close the hand spray gun: Release the safety le-
ver and trigger.

DANGER

Risk of injury! Switch the appliance off prior to replacing 
nozzle and activate hand spray gun until device is pres-
sureless.

Secure the trigger gun. To do so, push the safety 
catch towards the front.

Replacing the nozzle.

Set appliance switch to desired operating mode.
Indicator lamp for operational readiness lights up.

The device starts briefly and turns off, as soon as the 
working pressure is reached.

Note:

 If the indicator lamps for pump, rotation direction, 

burner malfunction or engine are on during operation, 
turn off the appliance immediately and repair malfunc-
tion, refer to "Help with malfunctions".

Release the trigger gun. To do so, push the safety 
catch towards the back.

When activating the hand spray gun the device switch-
es back on.

Note:

 If no water comes out of the high pressure nozzle, 

vent pump. Refer to "Help with malfunctions - appliance 
is not building up pressure".

Set temperature regulator to desired temperature.

30 °C to 98 °C

Clean with hot water.

100 °C to 150 °C

Clean using steam. 

In steam operation (> 100°C), use the steam noz-
zle available as an accessory (see “Steam opera-
tion”).

Water connection

Suck in water from vessel

Power connection

Operation

Opening/closing the trigger gun

Replace the nozzle

Turning on the Appliance

Adjust cleaning temperature

19

EN

Summary of Contents for HDS 9/18-4 M

Page 1: ...Register your product www kaercher com welcome HDS 9 18 4 M HDS 12 18 4 S 59682120 12 18 Espa ol 6 English 16...

Page 2: ...1 5 12 14 10 6 9 8 4 3 2 1 23 24 25 26 27 22 21 17 18 19 20 7 11 13 16 15 2...

Page 3: ...28 29 MIN MAX MAX MIN 30 31 32 33 34 35 36 38 37 39 3...

Page 4: ...2 3 4 5 6 4 5 6 7 8 9 13 A B C 10 11 12 2 1 3 1 2 2 1 4 5 3 2 2 1 4...

Page 5: ...7 8 9 10 6 7 8 9 5...

Page 6: ...e alta presi n acero 10 Conexi n el ctrica 11 Palanca de seguro 12 Caj n abatible 13 Palanca de disparo 14 Bloque de seguridad de la pistola pulverizadora manual 15 Pistola pulverizadora EASY Force 16...

Page 7: ...sorios Si se utiliza agua reciclada no se pueden superar los si guientes limites Respetar las normativas vigentes nacionales co rrespondientes para eyectores de l quidos Respetar las normativas vigent...

Page 8: ...iones El aparato los accesorios los tu bos de alimentaci n y las conexiones deben estar en perfecto estado Si no est n en perfecto estado no de ben utilizarse Active el freno de estacionamiento Figura...

Page 9: ...a de un dep sito de agua potable No aspire nunca l quidos que contengan disolventes como diluyente de laca ga solina aceite o agua sin filtrar Las juntas en el aparato no son resistentes a los disolve...

Page 10: ...presi n y caudal de la unidad de bomba Utilice los detergentes con moderaci n para no perjudicar el medio ambiente El detergente debe ser apropiado para la superficie que se ha de limpiar Ajustar la c...

Page 11: ...arato En largos periodos de inactividad o cuando no sea po sible el almacenamiento a salvo del hielo Vaciar el dep sito de detergente Dejar salir agua Enjuagar el aparato con anticongelante Desatornil...

Page 12: ...e arranque involuntariamente y descarga el ctrica Antes de efectuar cualquier trabajo en el aparato hay que desconectarlo de la red el ctrica Fuga en el sistema de alta presi n Verificar la estanqueid...

Page 13: ...dad de abastecimiento de agua ver datos t cnicos La bomba no es estanca Nota Lo permitido es 3 gotas por minuto En caso de fuga de mayor envergadura deje que el servicio t cnico revise el aparato Fuga...

Page 14: ...siempre que se deban a defectos de material o de fabricaci n En un caso de ga rant a le rogamos que se dirija con el comprobante de compra al distribuidor donde adquiri el aparato o al servicio al cl...

Page 15: ...de pieza boquilla de salida de vapor 2 114 004 0 2 114 009 0 Temperatura de trabajo m x agua caliente C 98 98 Temperatura de trabajo accionamiento por vapor C 155 155 Aspiraci n de detergente l h l m...

Page 16: ...Y Lock 8 Spray lance EASY Lock 9 High pressure nozzle stainless steel 10 Power supply 11 Safety lever 12 Folding compartment 13 Trigger 14 Safety latch of the hand spray gun 15 Trigger gun EASY Force...

Page 17: ...dent prevention of the respective country Fluid spray jets must be tested regularly and the results of these tests must be documented in writing The heating appliance of the machine is an ignition pla...

Page 18: ...ply in the float con tainer drop by drop The metering is set to medium water rigidity by the manufacturer Refill system care Determining the hardness of tap water through the public water supply works...

Page 19: ...to be ex ceeded In case of confusion regarding the power im pedance present on your connection please contact your utilities provider DANGER Danger of explosion Do not spray flammable liquids DANGER R...

Page 20: ...s 100 110 C De frosting of surcharge substances partially fa cade cleaning up to 140 C DANGER Scalding danger Set temperature regulator to desired temperature DANGER Scalding danger The work pressure...

Page 21: ...spray gun Switch on the pump with the power switch and al low to run for about 5 10 seconds Close the hand spray gun Set the appliance switch to 0 OFF Pull main plug out of socket with dry hands only...

Page 22: ...efective Inform Customer Service Temperature sensor defective Inform Customer Service Service interval Perform service work Fuel tank empty Refill fuel Note Burner can operate 5 more hours System care...

Page 23: ...gh the viewing glass have device checked by customer service Working pressure flow rate to high Reduce working pressure flow quantity at the pres sure volume regulator in the pump unit Sooty heating s...

Page 24: ...th steam using steam nozzle MPa bar 3 2 32 3 2 32 Part no of steam nozzle 2 114 004 0 2 114 009 0 Max operating temperature of hot water C 98 98 Working temperature steam operation C 155 155 Detergent...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...e Meinung Rate your product and tell us your opinion valuer votre produit et dites nous votre opinion Rese e su producto y d ganos su opini n www kaercher com welcome www kaercher com dealersearch Alf...

Reviews: