– 5
– For connection values, see technical
data and type plate.
– The electrical connections must be
done by an electrician according to IEC
60364-1.
Set the appliance switch to "0/OFF“.
Plug in the mains plug.
DANGER
Risk of injury on account of electric shock!
–
Unsuitable electrical extension cables
can be hazardous. Only use electrical
extension cables outdoors which have
been approved and labelled for this pur-
pose and have an adequate cable
cross-section.
–
Always unwind extension lines com-
pletely.
–
The plug and coupling of the extension
cable used must be watertight.
DANGER
Danger of explosion! Do not spray flamma-
ble liquids.
DANGER
Risk of injury! Never use the appliance
without the spray lance attached. Check
and ensure proper fitting of the spray lance
prior to each use. The screw connection of
the spray lance must be finger-tight.
DANGER
Risk of injury! Hold the hand spray gun and
the spray pipe firmly with both hands.
DANGER
Risk of injury! The trigger and safety lever
may not be locked during the operation.
DANGER
Risk of injury! Contact Customer Service if
the safety lever is damaged.
ATTENTION
–
Risk of damage! Never operate device
with an empty fuel tank. The fuel pump
will otherwise be destroyed. This also
applies to cold water operation.
–
Risk of damage! Never operate the ap-
pliance without a filter in the water con-
nection.
–
Risk of damage! Do not place any ob-
jects (hose, etc.) on or over the chim-
ney.
–
Device with hose drum:
Risk of damage. Always unwind high-
pressure hose completely.
Illustration
Unlock the hood lock using a screwdriv-
er, pivot the appliance hood forward
and unhook it.
Illustration
Hook in the appliance hood (see ar-
rows), pivot it up and lock in the hood
lock.
To open the trigger gun: Actuate the
safety lever and trigger.
To close the hand spray gun: Release
the safety lever and trigger.
DANGER
Risk of injury! Switch the appliance off prior
to replacing nozzle and activate hand spray
gun until device is pressureless.
Secure the trigger gun. To do so, push
the safety catch towards the front.
Replacing the nozzle.
Illustration
1 Operating with cold water
2 Operating with hot water
Set appliance switch to desired operat-
ing mode.
The device starts briefly and turns off, as
soon as the working pressure is reached.
Release the trigger gun. To do so, push
the safety catch towards the back.
When activating the hand spray gun the de-
vice switches back on.
Note:
If no water comes out of the high
pressure nozzle, vent pump.
Power connection
Operation
Open/close the hood
Opening/closing the trigger gun
Replace the nozzle
Operating modes
0/OFF = Off
Turning on the Appliance
8
EN