Screw off supply hose at boiler bot-
tom and drain heating spiral empty.
Î
Operate device for max. 1 minute
until the pump and conduits are
empty.
Note
Observe handling instructions of the
anti-freeze agent manufacturer.
Î
Fill anti-freeze agent of the trade into
swimmer container.
Î
Switch on appliance (without heater)
till the appliance has been complete-
ly rinsed.
A certain corrosion protection is
achieved with this as well.
DANGER
Risk of injury! Always disconnect the
device from the electrical power supply
before performing maintenance or re-
pair work.
몇
WARNING
Only use original spare parts.
After each work, turn off device, refer to
"After each operation".
Î
Set the appliance switch to "0".
Î
Disconnect the main plug from the
socket.
Î
Shut off water supply.
Î
Activate hand spray gun until device
is pressure less.
Î
Remove water connection.
Î
Allow device to cool down.
Your Kärcher vender will inform you
about the performance of a periodic
safety inspection resp. signing of a
maintenance contract.
Î
Clean the sieve in the water connec-
tion.
Î
Clean the fine filter.
Î
Check oil level.
In case of lacteous oil inform Kärcher
customer service immediately
Î
Clean sieve in the water shortage
safe guard.
Î
Clean filter at the detergent suck
hose.
Î
Oil change.
Figure 1 - Pos. 18
Î
Take out sieve.
Î
Clean sieve in water and reinstall.
Figure 8
Î
Unpressurize the appliance.
Î
Unscrew lid with filter.
Î
Clean the filter with clean water or
compressed air.
Î
Reinstall in reverse sequence.
Flush device with anti-freeze
agent
MAINTENANCE AND CARE
Maintenance intervals
Weekly
Monthly
After 500 operating hours, at least
annually.
MAINTENANCE TASKS
Clean the sieve in the water con-
nection
Cleaning the fine filter