Display
Corrective Action
– Increase water supply volume
– Clean strainer in water connection
– Clean strainer before the low-water safety device
– Replace the reed switch of the low-water safety device*
– Clean the low-water safety device*
– Repair leak in the high-pressure system
– Decarbonize heater element*
– Readjust burner*
– Replace exhaust gas thermostat*
– Check fuses and voltage on all 3 phases.*
– Replace air pressure switch*
– Check amount of fuel in tank
– Check that burner is functioning correctly*
– Check fuel nozzle, ignition electrodes and ignition cable,
and replace if required*
– Clean burner*
– Motor overload
– Winding thermo-protection or thermal relay has triggered
– Remove cause of motor overload
7. Troubleshooting
7.1
FAULT warning light is illuminated
•••••
This warning light illuminates if there is a fault.
•••••
When you open the storage compartment
cover flap, you will see the electronic display
in the view window.
•••••
The warning light extinguishes when you
have corrected the fault and switched the
appliance back on.
F
1
F
2
F
3
F
4
F
5
Always disconnect the appliance from
the electric mains supply before carrying
out any repair work.
F
6
F
7
* These faults should be corrected by Customer Service or a qualified electrician only.
Summary of Contents for HDS 2000 SUPER
Page 1: ...HDS 2000 Super 5 956 535 A 2009680 11 04 www kaercher com...
Page 3: ......
Page 98: ...HDS 2000 Super 98 GR 4 4 1 4 2 4 3 4 4 3 4 5 4 6 RM 110...
Page 100: ...HDS 2000 Super 100 GR 5 5 1 10 5 2 25 0 40 5 3 Servopress 5 4 5 5 30 50 C 60 C 60 90 C...
Page 102: ...HDS 2000 Super 102 GR 5 6 3 4 5 6 1 1 5 2 0 1 5 9 30 5 10...
Page 103: ...HDS 2000 Super GR 103 6 6 1 A...
Page 104: ...HDS 2000 Super 104 GR 6 6 2 6 3 6 4 3 6 5 3 6 6 8 6 7 1 0 C...
Page 105: ...HDS 2000 Super GR 105 REED 3 7 7 1 F 1 F 2 F 3 F 4 F 5 F 6 F 7...
Page 106: ...HDS 2000 Super 106 GR 7 7 2 RM 110 4 7 7 3 5 3 7 4 5 7 5 7 6 7 7...
Page 107: ...HDS 2000 Super GR 107 8 8 1 2 Servopress 8 2 8 3 8 4...