![Kärcher HD 855 S Operating Instructions Manual Download Page 21](http://html1.mh-extra.com/html/karcher/hd-855-s/hd-855-s_operating-instructions-manual_654044021.webp)
English
Operating Instructions HD 855 S(X) / HD 895 S(X)
21
n
Check all supply lines to the pump for
leaks or obstructions.
n
Seek the help of Customer Service if
necessary.
Pump is leaky
n
Three drops per minute are allowable
and can appear on the underside of the
cleaner. Seek the help of Customer
Service if leaks are more serious.
Pump makes a knocking
noise
n
Check all supply lines as well as the
detergent system for leaks.
n
Evacuate air from the cleaner.
n
Seek the help of Customer Service if
necessary.
Detergent is not being drawn
in
n
Set nozzle to “low pressure”.
n
Check detergent suction hose with filter
for leaks or obstructions and clean it if
necessary.
n
Clean/renew non-return valve in
detergent suction-hose connection.
n
Open detergent metering valve or check
it for leaks/remove obstruction. Also
clean venting orifice in the cap.
n
Seek the help of Customer Service if
necessary.
Spare parts
You will find a list of spare parts at the end
of these operating instructions.
EU Declaration of
Conformity
We hereby declare that the equipment described below
conforms to the relevant fundamental safety and health
requirements of the appropriate EU Directives, both in
its basic design and construction as well as in the
version marketed by us.
This declaration will cease to be valid if any
modifications are made to the machine without our
express approval.
Product:
High-pressure cleaner
Model:
1.086-xxx, 1.087-xxx
Relevant EU Directives:
EU Machinery Directive (98/37/CE)
EU Low-Voltage Equipment Directive (73/23/EEC)
amended by 93/68/EEC
EU Directive on Electromagnetic Compatibility
(89/336/EEC) amended by 91/263/EEC, 92/31/EEC,
93/68/EEC
EC directive on noise emissions (2000/14/EU)
Harmonised standards applied:
DIN EN 60 335-1
DIN EN 60 335-2-79
DIN EN 55 014-1: 2000 + A1 : 2001
DIN EN 55 014-2: 1997
DIN EN 61 000-3-2: 2000
DIN EN 61 000-3-11: 2001
National standards applied: –
Applied conformity evaluation procedure: Appendix V
Measured sound power level:
91 dB(A) / HD 895 // 85 dB(A) / HD 855
Guaranteed sound power level:
92 dB(A) / HD 895 // 86 dB(A) / HD 855
Appropriate internal measures have been taken to
ensure that series-production units conform at all times
to the requirements of current EU Directives and
relevant standards.
The signatories are empowered to represent and act
on behalf of the company management.
Alfred Kärcher GmbH & Co.
Cleaning Systems
D-71349 Winnenden
Alfred Kärcher Kommanditgesellschaft.
Sitz Winnenden.
Registergericht: Waiblingen, HRA 169.
Persönlich haftende Gesellschafterin:
Kärcher Reinigungstechnik GmbH. Sitz Winnenden,
2404 Registergericht Waiblingen, HRB
Geschäftsführer: Dr. Bernhard Graf, Hartmut Jenner,
Georg Metz
S. Reiser
H. Jenner
5959-797.book Seite 21 Dienstag, 7. Januar 2003 12:02 12
Summary of Contents for HD 855 S
Page 1: ...www karcher com HD 855 S SX HD 895 S SX 5 959 797 A 2003483 07 02 ...
Page 3: ......
Page 4: ...4 ...
Page 5: ...5 1 2 3 ...
Page 215: ......
Page 216: ......