background image

– 3

Warning

The appliance may only be connected to al-
ternating current.
The appliance may only be connected to an 
electrical supply which has been installed in 
accordance with IEC 60364.
The voltage indicated on the type plate 
must correspond to the voltage of the elec-
trical source.
The minimum fuse rating required at the 
socket outlet is (see technical specifica-
tions).
It is recommended that you connect this de-
vice to a socket that has a 30 mA protection 
switch against wrong currents.
Check the power cord with mains plug for 
damage before every use. If the power cord 
is damaged, please arrange immediately 
for the exchange by an authorized custom-
er service or a skilled electrician.
The plug and coupling of the extension ca-
ble used must be watertight.
Use the extension cord that has an ade-
quate cross-section (see "Technical Data") 
and unwind it fully from the cable drum.
Unsuitable extension cables can be haz-
ardous. Only use extension cables out-
doors which have been approved for this 
purpose and labelled with a sufficient cable 
cross section:

For connection values, see type plate/tech-
nical data.

Warning

Observe regulations of water supplier. 
According to the applicable regula-
tions, the appliance must never be 
used on the drinking water supply 
without a system separator. Use a 
suitable system separator manufactured by 
KÄRCHER; or, as an alternative, a system 
separator as per EN 12729 Type BA. Water 

flowing through a system separator is con-
sidered non-drinkable. 

Caution

Always connect the system separator to 
the water supply, never directly to the appli-
ance!

For connection values refer to technical 
specifications

Connect the supply hose (minimum 
length 7.5 m, minimum diameter 3/4“) to 
the water connection point of the ma-
chine and at the water supply point (for 
e.g. a tap). 

Note

The supply hose is not included.

Open the water supply.

Screw the suction hose with filter (order 
no. 4.440-238.0) to the water connec-
tion.

Deaerate the appliance:
Unscrew the nozzle. 
Switch on the appliance and let it run 
until the water exiting is bubble-free. 
At the end let the appliance run for ap-
prox. 10 seconds - then switch off. Re-
peat the procedure for a couple of 
times.

Switch off the appliance and fit the noz-
zle again. 

Danger

If the appliance is used in hazardous areas 
(e.g. filling stations) the corresponding 
safety provisions must be observed.

Warning

Clean engines only at places with corre-
sponding oil separators (environmental 
safety).
Only for HD 600:

Danger

Long hours of using the appliance can 
cause circulation problems in the hands on 
account of vibrations. 

Start up

Electrical connection

Water connection

Connection to the water supply

Drawing in water from open reservoirs

Operations

13

EN

Summary of Contents for HD 600

Page 1: ...English 11 Fran ais 19 Italiano 27 Nederlands 35 Espa ol 43 Portugu s 51 Dansk 59 Norsk 66 Svenska 74 Suomi 81 89 T rk e 98 106 Magyar 115 e tina 123 Sloven ina 131 Polski 138 Rom ne te 146 Sloven in...

Page 2: ...2...

Page 3: ...e country Fuel spray jets must be tested regularly and the results of these tests must be documented in writing Danger Immediate danger that can cause severe injury or even death Warning Possible haza...

Page 4: ...n side of the pump The overflow valve pressure switch and safety valve are set and sealed at the fac tory Setting only by customer service Notes about the ingredients REACH You will find current infor...

Page 5: ...er supply without a system separator Use a suitable system separator manufactured by K RCHER or as an alternative a system separator as per EN 12729 Type BA Water flowing through a system separator is...

Page 6: ...ergents can cause damage to the appliance and to the object to be cleaned Use only those detergents that have been approved by K rcher Observe the dosage and other instructions provided with these det...

Page 7: ...out any tasks on the machine Note Please dispose off used oil only in the col lection points provided for them Please hand over old oil if any only at such plac es Polluting the environment with used...

Page 8: ...act Customer Service if needed 3 drops per minute are permitted and can come out from the lower side of the appli ance Call Customer Service if there is heavy leakage With stronger leak have device ch...

Page 9: ...cease to be valid if the machine is modified without our prior approval The undersigned act on behalf and under the power of attorney of the company man agement Authorised Documentation Representative...

Page 10: ...150 Max operating over pressure MPa bar 12 5 125 17 5 175 Flow rate l h l min 240 650 4 10 8 250 700 4 2 11 6 250 700 4 2 11 7 Nozzle size 050 065 045 Detergent suck in l h l min 0 40 0 0 7 Max recoi...

Page 11: ......

Reviews: