background image

– 8

Specifications

Type

HD 600

HD 600

HD 715

Main Supply

Voltage

V

230

230

400

Current type

Hz

1~ 50

3~ 50

Connected load

kW

3,0

2,2

4,7

Mains fuse (slow-blow)

A

13

10

16

Type of protection

IPX5

Extension cable 10 m

mm

2

1,5

Extension cord 30 m

mm

2

2,5

Water connection

Max. feed temperature

°C

60

Min. feed volume

l/h (l/min)

900 (15)

Suck height from open container (20 °C) m

0,5

Max. feed pressure

MPa (bar)

1 (10)

Performance data

Working pressure

MPa (bar)

11 (110)

8 (80)

15 (150)

Max. operating over-pressure

MPa (bar)

12,5 (125)

17,5 (175)

Flow rate

l/h (l/min)

240...650 

(4...10,8)

250...700 

(4,2...11,6)

250...700 

(4,2...11,7)

Nozzle size

050

065

045

Detergent suck in

l/h (l/min)

0...40 (0...0,7)

Max. recoil force of hand spray gun

N

30

Values determined as per EN 60355-2-79

Noise emission
Sound pressure level L

pA

dB(A)

78

Uncertainty K

pA

dB(A)

1

Sound power level L

WA

 + Uncertainty 

K

WA

dB(A)

98

95

Hand-arm vibration value
Hand spray gun

m/s

2

2,8

<2,5

Spray lance

m/s

2

2,8

<2,5

Uncertainty K

m/s

2

1

Fuel

Amount of oil

l

0,5

0,6

Oil grade

SAE 15W40

Dimensions and weights

Length

mm

500

Width

mm

310 

Height

mm

350

Weight without accessories

kg

32,5

32,4

36,5

18

EN

Summary of Contents for HD 600

Page 1: ...English 11 Fran ais 19 Italiano 27 Nederlands 35 Espa ol 43 Portugu s 51 Dansk 59 Norsk 66 Svenska 74 Suomi 81 89 T rk e 98 106 Magyar 115 e tina 123 Sloven ina 131 Polski 138 Rom ne te 146 Sloven in...

Page 2: ...2...

Page 3: ...e country Fuel spray jets must be tested regularly and the results of these tests must be documented in writing Danger Immediate danger that can cause severe injury or even death Warning Possible haza...

Page 4: ...n side of the pump The overflow valve pressure switch and safety valve are set and sealed at the fac tory Setting only by customer service Notes about the ingredients REACH You will find current infor...

Page 5: ...er supply without a system separator Use a suitable system separator manufactured by K RCHER or as an alternative a system separator as per EN 12729 Type BA Water flowing through a system separator is...

Page 6: ...ergents can cause damage to the appliance and to the object to be cleaned Use only those detergents that have been approved by K rcher Observe the dosage and other instructions provided with these det...

Page 7: ...out any tasks on the machine Note Please dispose off used oil only in the col lection points provided for them Please hand over old oil if any only at such plac es Polluting the environment with used...

Page 8: ...act Customer Service if needed 3 drops per minute are permitted and can come out from the lower side of the appli ance Call Customer Service if there is heavy leakage With stronger leak have device ch...

Page 9: ...cease to be valid if the machine is modified without our prior approval The undersigned act on behalf and under the power of attorney of the company man agement Authorised Documentation Representative...

Page 10: ...150 Max operating over pressure MPa bar 12 5 125 17 5 175 Flow rate l h l min 240 650 4 10 8 250 700 4 2 11 6 250 700 4 2 11 7 Nozzle size 050 065 045 Detergent suck in l h l min 0 40 0 0 7 Max recoi...

Page 11: ......

Reviews: