background image

English

11

Pump is leaky

„

Three drops per minute are allowable and 
can appear on the underside of the unit. 
Seek the help of Customer Service if leaks 
are more serious.

Pump makes a knocking noise

„

Check all supply lines as well as the deter-
gent system for leaks.

„

Close the cleaning agent metering valve 
when running the unit without cleaning 
agent.

„

Evacuate air from the cleaner (see Switch-
ing on the unit).

„

Seek the help of Customer Service if nec-
essary.

Detergent is not being drawn in

„

Set nozzle to "Chem".

„

Check detergent suction hose with filter for 
leaks or obstructions and clean it if neces-
sary.

„

Open detergent metering valve or check it 
for leaks/remove obstruction.

„

Seek the help of Customer Service if nec-
essary.

Spare parts

You will find a list of spare parts at the end of 
these operating instructions.

Warranty

The warranty terms issued by our authorised 
marketing company are valid in every country. 
We remedy any fault in the unit free of charge 
within the warranty period providing the cause 
of the fault proves to be a material or manu-
facturing error.

The warranty only becomes operative when 
your dealer has completed the reply card ac-
companying the sale of the unit, has stamped 

and signed it and you have then sent the reply 
card to the marketing company in your coun-
try.

Should you wish to call upon the guarantee, 
please apply to your dealer or nearest author-
ised Customer Service centre taking along 
also the accessories and bill of sale.

Summary of Contents for HD 2.3/14 C Ed Food

Page 1: ...www kaercher com HD 2 3 15 C Ed HD 3 0 20 C Ea HD 2 3 14 C Ed Food 5 961 971 0 03 07...

Page 2: ...2 English 4 Fran ais 13 Espa ol 22...

Page 3: ...3...

Page 4: ...ger Gun Safety Lock PREVENTS the trigger from accidentally being engaged This safety feature DOES NOT lock trigger in the ON position Do not use extension cord with this unit GROUNDING INSTRUCTIONS Th...

Page 5: ...se of penetration seek medical aid immediately This system is capable of producing 10400 kPa 1500 PSI HD 2 3 15 C Ed 13000 kPa 2000 PSI HD 3 0 20 C Ea to avoid rupture and injury do not operate this p...

Page 6: ...ad these operating instructions and take special note of the accompanying booklet Safety Instructions for High Pressure Clean ers No 5 951 949 Use of the cleaner Use this appliance exclusively for cle...

Page 7: ...er Mount the accessories Mount nozzle on the spray lance see markings on the top of the setting ring Fit the spray lance to the hand held spray gun For appliances without hose reel Undo push handle cl...

Page 8: ...f necessary allow unit to continue running for 10 sec onds and then switch off Repeat this pro cedure several times Switch off the unit and screw the nozzle back on Operating the unit Danger Observe t...

Page 9: ...ugh for one minute Interrupting the operation Release lever of the handgun the unit switches off Retract lever again and the unit switches on again Switching the unit off Set unit switch to 0 and pull...

Page 10: ...ng hours Change the oil For oil quantity and type see Technical Specifications Undo the fastening screw remove the hood remove the oil tank cover tilt unit Drain oil into a suitable container Fill slo...

Page 11: ...or check it for leaks remove obstruction Seek the help of Customer Service if nec essary Spare parts You will find a list of spare parts at the end of these operating instructions Warranty The warrant...

Page 12: ...ner 20 C ft m 1 6 0 5 1 6 0 5 1 6 0 5 Supply pressure max psi MPa 145 1 145 1 145 1 Performance data Operating pressure psi MPa 1500 10 3 2000 13 8 1400 9 7 Max operating overpressure safety valve psi...

Page 13: ......

Reviews: