background image

Operating Instructions HD 994... / HD 1094... / HD 1294...

English

16

Preparing the cleaner 
for use

Unpack the cleaner

– When unpacking the cleaner, check the 

contents of the packaging. If there has 
been any damage in transit inform the 
dealer.

– Do not dispose of the packaging with the 

household rubbish, hand it in at the 
appropriate collection point for recycling.

Check the oil level

n

Screw out the fastening screws on the left 
and right of the unit cover, remove unit 
cover.

n

Cut off the tip on the cover to the oil 
reservoir.

n

Check the oil level in the oil reservoir.

n

Fasten the unit cover.

Mount the accessories

n

Attach the handle (only for units which do 
not include a hose reel, bolts and nuts).

Information:
If the handle is too low, it can be altered 

as follows:

n

Remove the handle and hood.

n

Unscrew the fastening nut for the detergent 
tank and remove the tank.

n

Unscrew the mounting rail from the motor 
unit (3 screws) and remove towards the 
rear.

n

Turn the mounting rail so that top and 
bottom are interchanged.

n

Screw the mounting rail back on to the 
motor unit using the 3 new fastening holes. 
The mounting rail now projects upwards by 
another 85 mm.

n

Re-attach the detergent tank, hood and 
handle.

n

Mount nozzle on the spray lance (see 
markings on the top of the setting ring).

n

Mount spray lance on the handgun.

For appliances with hose reel:

n

Insert the crank into the hose reel shaft and 
tighten the screw.

n

Connect the high-pressure hose to the 
handgun.

For handguns with threaded connection:

n

Screw the high-pressure hose on tight.

For handguns without threaded connection:

n

Lever off retaining clasp on handgun with 
a screwdriver.

n

Stand handgun on end and while holding it 
in this position, push end of hose into pistol 
as far as end stop. Ensure that loose disc 
on end of hose drops all way to bottom.

n

Push retaining clasp back into handgun. 
When attached properly, high-pressure 
hose can only be pulled out by approx. 
1 mm.. If hose can be pulled out further, the 
disc has been incorrectly fitted.

n

It is advisable to lay the high-pressure hose 
out in a straight line before reeling it up.

n

Wind the high-pressure hose up in even 
layers on the hose reel by turning the crank 
handle.

Using the cleaner for the 
first time

Electrical connection

Caution!
The voltage specified on the model 

rating plate must correspond to the voltage 
supplied.

Caution!
Use an extension cable whose cable 

cross-section is adequate (10 m = 2,5 mm²) 
and unreel it completely from the cable drum. 
For connected loads see model rating plate/
Technical Specifications.

i

Summary of Contents for HD 1094

Page 1: ...www karcher com HD 994 994 Plus 994 SX Plus HD 1094 1094 Plus 1094 SX Plus HD 1294 1294 Plus 1294 SX Plus 5 959 949 A 2004338 09 02 ...

Page 2: ...taliano Nederlands Español Português Dansk Norsk Svenska Suomi r w 5ÔSL F 3 FF Ï BHZBS FTLZ 4MPWFOTLZ 1PMTLJ 3PN OF UF 4MPWFOTLP SWBUTLJ 4SQTLJ b DSF Ï 6 15 23 32 41 49 58 67 75 83 91 99 108 117 126 134 142 150 159 167 175 183 191 ...

Page 3: ......

Page 4: ...4 HD 994 994 Plus HD 1094 1094 Plus HD 1294 1294 Plus ...

Page 5: ...5 HD 994 SX Plus HD 1094 SX Plus HD 1294 SX Plus ...

Page 6: ...cial note of the accompanying booklet Safety Instructions for High pressure Cleaners No 5 951 949 Use of the cleaner Use this cleaner exclusively for cleaning with high pressure jet and detergent e g cleaning of machines vehicles buildings tools cleaning with high pressure jet without detergent e g cleaning facades terraces gardening equipment For stubborn dirt we recommend the dirt blaster as an ...

Page 7: ...rgent tank hood and handle n Mount nozzle on the spray lance see markings on the top of the setting ring n Mount spray lance on the handgun For appliances with hose reel n Insert the crank into the hose reel shaft and tighten the screw n Connect the high pressure hose to the handgun For handguns with threaded connection n Screw the high pressure hose on tight For handguns without threaded connecti...

Page 8: ... vent the unit unscrew the nozzle and leave the unit running until the water exits with no air bubbles Switch off the unit and screw the nozzle back on Operating the cleaner Danger Observe the relative safety regulations when using the cleaner at filling stations or other high risk areas Caution Only clean engines in places which have appropriate oil separators protection of the environment Cautio...

Page 9: ...cher Proportions of detergent to be used and accompanying instructions should be noted carefully Use detergents sparingly out of consideration for the environment Kärcher cleaning agents guarantee trouble free operation Please seek advice or ask for our catalogue of information sheets on cleaning agents n Fill detergent reservoir n Set nozzle to n Set the detergent metering valve to the desired co...

Page 10: ... you obtain a sure protection against corrosion Care and maintenance Danger Before undertaking any care or maintenance work on the cleaner pull out the power plug Caution When changing the oil dispose of any waste oil only at authorised collection points Safety inspection maintenance contract You can arrange with your dealer to have a regular safety inspection carried out or to have a maintenance ...

Page 11: ...rised Customer Service personnel For faults which are not identified in this chapter or when in doubt or when expressly instructed to do so consult authorised Customer Service personnel Cleaner does not work n Check mains voltage n Check connecting cable for damage n If the motor has overheated let the cleaner cool down Then switch it on again n Consult Customer Service if there is an electrical f...

Page 12: ...health requirements of the appropriate EU Directives both in its basic design and construction as well as in the version marketed by us This declaration will cease to be valid if any modifications are made to the machine without our express approval Product High pressure cleaner Model 1 112 xxx 1 951 xxx Relevant EU Directives EU Machinery Directive 98 37 CE EU Low Voltage Equipment Directive 73 2...

Page 13: ... Supply hose minimum diameter inches 3 4 3 4 3 4 Suction height from an open container 20 C m 1 1 1 Supply pressure max bar 10 10 10 Performance data Operating pressure MPa bar 1 19 10 190 1 21 5 10 215 2 17 20 170 Flow rate l h l min 300 900 5 15 300 900 5 15 300 1000 5 16 7 500 1290 8 4 21 5 Detergent intake l h l min 0 60 0 1 0 70 0 1 2 0 70 0 1 2 Recoil force of the handgun N 55 55 55 Noise em...

Page 14: ... 4 580 238 0 4 760 355 0 6 303 025 0 5 321 493 0 4 760 355 0 2 880 296 0 6 362 532 0 6 362 524 0 2 880 296 0 6 647 379 0 400 V 6 647 401 0 230 V 4 767 004 0 HD 1094 4 767 007 0 HD 1294 4 775 254 0 HD 1094 4 775 254 0 HD 1294 4 775 363 0 HD 994 6 389 856 0 HD 1094 6 389 856 0 HD 1294 6 389 853 0 HD 994 4 763 105 0 HD 994 2 880 296 0 6 362 365 0 6 389 891 0 6 363 116 0 HD 1094 6 363 116 0 HD 1294 6 ...

Page 15: ...1 0 6 362 161 0 5 310 076 0 6 343 137 0 6 414 141 0 31 01 2001 4 580 238 0 4 760 355 0 6 303 025 0 5 321 493 0 4 760 355 0 2 880 296 0 6 362 532 0 6 362 524 0 6 647 379 0 400 V 6 647 401 0 230 V 0 I 4 775 283 0 6 390 171 0 2 880 296 0 6 362 365 0 6 390 171 0 4 763 105 0 HD 994 SX 4 767 004 0 HD 1094 SX 4 767 007 0 HD 1294 SX ...