English
5
CAUTION
When connecting the water inlet to the water
supply mains, local regulations of your water
company must be observed. In some areas
the unit must not be connected directly to the
public drinking water supply. This is to ensure
that there is no feedback of chemicals into the
water supply. Direct connection via a receiver
tank or backflow preventer, for example, is
permitted.
Dirt in the feed water will damage the unit. To
avoid this risk, we recommend fitting a water
filter.
Garden hose must be at least 5/8 inch in di-
ameter.
Flow rate of water supply must not fall below
2.5 GPM (gallons per minute).
Flow rate can be determined by running the
water for one minute into an empty 5-gallon
container.
The water supply temperature must not ex-
ceed 104°F/40°C.
Never use the pressure washer to draw in wa-
ter contaminated with solvents, e.g. paint thin-
ners, gasoline, oil, etc.
Always prevent debris from being drawn into
the unit by using a clean water source. Use
additional water filter.
Do not operate pressure washer without the
water turned on.
WATER SUPPLY
(Cold Water Only)
ASSEMBLY INSTRUCTIONS
Required Tools (not included)
Description
1/2” (or 13mm) Socket Wrench
7/16” (or 11mm) Socket Wrench
Flat srew driver
Hardware (included)
Description
Purpose
Illustration
Qty
A
Joint
Joint assembly
2