background image

English

NT 361 Eco / NT 361 Eco TE / NT 561 Eco / NT 561 Eco TE

5

IN ALL
CASES,
MAKE SURE
THE
RECEPT-
ACLE IN
QUESTION IS
PROPERLY
GROUNDED.

NEVER
REMOVE
GROUNDING
PRONG
FROM

POWER
PLUG.

EXTENSION
CORDS

Use only three-wire extensions
cords that have three-pong
grounding-type plugs and three-pole
receptacle that accepts the
appliance's plug. Replace damaged
or worn cord immediately.

DO NOT
ATTEMPT
TO REPAIR
POWER
CORD.

Figure A

1. Groundet outlet box
2. Current carrying prongs

Grounding prong is longest of the
3 prongs

Figure B

1. Groundet outlet box
2. Grounding means
3. Adapter

SERVICING
OF DOUBLE-
INSULATED
APPLIANCES

In a double-insulated appliance, two
systems of insulation are provided
instead of grounding. No grounding
means is provided on a double-
insulated appliance, nor should a
means for grounding be added to
the appliance. Servicing a double-
insulated appliance requires
extreme care and knowledge of the
system, and should be done only by
qualified service personnel.
Replacement parts for a double-
insulated appliance must be
identical to the parts they replace.

Summary of Contents for ECO TEA NT 361

Page 1: ...NT 361 Eco NT 361 Eco TE NT 561 Eco NT 561 Eco TE www kaercher com 5 959 693 A2009775 12 04...

Page 2: ...Accessoires 26 27 Caract ristiques techniques Sch ma de c blage Liste des pi ces de rechange 28 29 30 Cet appareil est adapt l usage professionnel p ex dans les h tels les coles les h pitaux les usin...

Page 3: ...ORD for damage or signs of any aging before each use 4 DO NOT PULL OR CARRY VACUUM CLEANER BY CORD Do not close door and cord or pull cord around sharp edges 5 KEEP CORD AWAY FROM HEAT AND OIL Do not...

Page 4: ...a path of least resistance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipmentgrounding conductor and ground plug The plug must be inse...

Page 5: ...tlet box 2 Current carrying prongs Grounding prong is longest of the 3 prongs Figure B 1 Groundet outlet box 2 Grounding means 3 Adapter SERVICING OF DOUBLE INSULATED APPLIANCES In a double insulated...

Page 6: ...NT 361 Eco NT 361 Eco TE NT 561 Eco NT 561 Eco TE 6...

Page 7: ...nd lock it in place Fitting the membrane filter Unlock and remove the suction head Pull the membrane filter over the container edge Replace the suction head and lock it in place Note The paper filter...

Page 8: ...ilter Insert power plug Switch on the machine and start using it Note Power Filter Clean is activated automatically hammering noise when sucking up water from a full container Clean and dry the surfac...

Page 9: ...ine The suction turbine switches off Empty the container Suction force diminishes Remove clogging material from the suction nozzle suction pipe Power Filter Clean suction hose or surface filter Activa...

Page 10: ......

Page 11: ...roved Sachet filtre 2 paisseurs Contr l BIA C Filtert te 2 lagig BIA C gep ft Paper filter bag double layered BIA C approved Sachet filtre 2 paisseurs Contr l BIA C Membranfilter Diaphragm filter Filt...

Page 12: ...T 361 Eco NT 361 Eco TE 34 l NT 561 Eco NT 561 Eco TE 45 l NT 361 Eco NT 361 Eco TE 20 l NT 561 Eco NT 561 Eco TE 31 l max 54 l s max 23 5 kPa NT 361 Eco NT 361 Eco TE 505 mm x 370 mm x 535 mm NT 561...

Page 13: ...ine Interrupteur de Turbine S2 Umschalter Betriebsart Switch Inverseur X1 Stecker Plug Fiche X2 X5 Steckkupplung Plug In Coupling Raccord Prise X6 Steckdose Socket Prise de Courant Nur f r Variante TE...

Page 14: ...NT 361 Eco NT 361 Eco TE NT 561 Eco NT 561 Eco TE 30...

Page 15: ...903 284 0 6 903 277 0 6 903 278 0 5 031 718 0 6 363 078 0 6 906 208 0 5 031 703 0 6 906 208 0 2 639 690 0 6 904 206 0 6 904 191 0 NT 561 ECO TE 6 435 197 0 5 031 601 0 5 031 601 0 6 904 215 0 6 435 3...

Reviews: