Kärcher CW 100 Manual Download Page 8

13

5.956-723

English

6. In the event of malfunction

The brush and suction motor is switched off via the built-in
electronic system

Brush is blocked

Withdraw mains plug, check brush for any dirt and if
necessary remove the blockage. The unit now has to be
restarted.

Suction turbine switches off, brush head carries on
functioning
 

(red indicator light goes off)

Thermal switch has disengaged motor due to overheating

Withdraw mains plug, exchange blocked filter or eliminate
suction hose blockage. After approximately 20 minutes, the
unit will start up again.

Suction hose is blocked

Switch off the unit. Remove the flexible hose from the housing and
pull it straight. Use something long to release hose blockage.

The suction hose can be disconnected from the unit by
pressing the locking lever. <Figure 11>

Connecting hose is blocked

The connecting hose can be removed by pulling out both
ends. Remove the blockage. <Figure 12>

Connection cable not inserted properly

Connect the upper section of the vacuum cleaner to the brush
head. Connect the hose to the brush head and upper section
of vacuum cleaner. Plug the connecting cable with connector
into the socket on the upper section (plug must audibly click into
place). <Figure 13>

Brushes in brush head are not rotating, suction turbine is
running

Hand pipe is not pushed into motor housing properly, or end is
worn down

If the end of the pipe has been worn down (due to vacuuming
without first fitting the crevice or upholstery nozzle), the end
switch will not be actuated and the brushes will not rotate.

Separating the brush head from the upper section of the
vacuum cleaner

Undo the connecting cable, release the plug by pressing in a
pointed object (e.g. screwdriver). <Figure 14>

The connecting hose can be removed by pulling out the two
ends.

Undo both screws at the side of the upper section to the
vacuum cleaner.

Figure 11

Figure 12

Figure 14

Figure 13

Summary of Contents for CW 100

Page 1: ...5 956 723 07 01 A0013445 CW 100...

Page 2: ...n a De bedes l se denne driftsvejledning igennem f r idrifttagningen i denne forbindelse skal is r Sikkerhedsforskrifter overholdes F r ibruktaking m bruksanvisningen leses n ye og det m taes hensyn t...

Page 3: ...zare i respecta i n mod special Instruc iunile de siguran Pred prvo pripravo za uporabo preberite ta navodila za uporabo in posvetite posebno pozornost poglavju Varnostni napotki Prije pu tanja u rad...

Page 4: ...kg 9 5 Sound pressure level acc to EN 60704 dB A 66 Power cable Typ H05VV F2x1 subject to technical modifications 1 Brush head with brush monitoring 2 Vacuum cleaner upper section 3 Recessed handle 4...

Page 5: ...Plug the connecting cable with connector into the socket on the upper section plug must audibly click into place Figure 3 3 2 Storing and removing cable The vacuum cleaner s power cable can be wounde...

Page 6: ...rvised by electronic brush monitoring not illuminated brush functioning properly orange light on set the pile height adjusting knob at a lower pile height orange light on even at the lowest setting ch...

Page 7: ...anging the filter bag approximately 20 times exchange safety filter Press cover fastener and remove cover Lift the red locking device and pull out the safety filter Assembly Lift the red locking devic...

Page 8: ...be removed by pulling out both ends Remove the blockage Figure 12 Connection cable not inserted properly Connect the upper section of the vacuum cleaner to the brush head Connect the hose to the brush...

Page 9: ...signatories are empowered to represent and act on behalf of the company management F D claration de conformit europ enne Par la pr sente nous d clarons que la machine ci apr s r pond de par sa concep...

Page 10: ...ctiva comunitaria sobre equipos de baja tensi n CEE 73 23 modificada mediante CEE 93 68 Directiva sobre compatibilidad electromagn tica CEE 89 336 modificada mediante CEE 91 263 CEE 92 31 y CEE 93 68...

Page 11: ...ss tt och i av oss levererat utf rande motsvarar till mpliga baskrav betr ffande s kerhet och h lsa enligt EU direktiven Vid ndringar p maskinen som icke avtalats med oss upph r denna f rs kran att g...

Page 12: ......

Page 13: ...0 0 CW 100 1 057 101 0 1 057 102 0 GB 1 057 103 0 CH 1 057 104 0 AUS 1 057 105 0 USA CDN 6 905 531 0 6 900 233 0 7 312 015 0 6 303 271 0 5 046 626 0 7 312 163 0 2 883 478 0 A 6 647 546 0 1 057 102 0 6...

Reviews: