18
9. TECHNICAL DATA
Power Connection
Voltage ...................................................... 230-240
V -AC
Current ........................................................... 1~50
Hz
Connected/Load ................................................. 1.9
KW
Mains Fuse ........................................................ 13
AMP
Water Connection
Supply Temperature (Max) ................................ 40
°C
Supply Rate (Min) ............................................ 600
Litres per Hour
Supply Pressure (Max) ...................................... 12
bar
Supply Hose Length ......................................... 7.5
metres
Diameter ...................................... 1/2
inch
Performance Data
Pump Pressure (Max) ....................................... 130
bar
Operating Pressure ........................................... 120
bar
Flow Rate .......................................................... 400
litres per hour
Detergent Intake ................................................. 20
litres per hour
Recoil Force of Hand Held Spray Gun
at Operating Pressure (Max) ............................... 15
N
Unit vibrations ................................................... 0.8
m/s²
Noise ................................................................ 74,5
dB (A)
Optimum Working Distance on High Pressure .. 30
cm
Dimensions
Length ............................................................... 395
mm
Width ................................................................. 315
mm
Height ............................................................... 935
mm
Weight ................................................................. 12
Kg
Circuit Diagram
C1
Capacitor
M1
Motor
Q1
Switch
T
Temperature limiter
S1
Pressure switch