Technical Data

Power connection
Voltage (1~60 Hz) ............................ 120 V
Connected load ................................. 1,5 kW

(2,0 hp)

Mains fuse (slow) ............................... 15 A
Protection class .................................... II
Water connection
Supply temperature (max.) ................ 60 °C

(140 °F)

Supply rate (min.) ............................ 600 l/h

(2.5 gpm)

Supply pressure (max.) ..................... 12 bar

(170 psi)

Supply hose ...........................................
 - length (min.) ................................... 7,5 m

(25 ft)

 - diameter (min.) .............................. 1/2 in
Suction height from open tank at a
 water temperature of 20°C (68°F) ...... 1 m

(3 ft)

Performance data
Rated pressure .................. 1000-10300 kPa(150-1500 psi)
Flow rate ........................................... 450 l/h

(1.8 gpm)

Detergent intake ............................. 0–25 l/h

(0-7 gph)

Recoil force of hand-held spray gun
at operating pressure (max.) ............. 19 N
Sound pressure level (DIN 45635) ... 74 dB (A)
Dimensions
Length ............................................... 508 mm

(20 in)

Width ................................................ 255 mm

(10 in)

Height ............................................... 284 mm

(11,2 in)

Weight with accessories ................. 15,5 kg

(34 lbs)

Circuit Diagram

C1 Running capacitor
F1 Temperature  fuse
M1 Motor
S1 Appliance switch
S2 Pressure-operated switch

Données techniques

Branchement électrique
Tension(1~60 Hz) ............................ 120 V
Puissance raccordée ........................ 1,5 kW

(2,0 hp)

Fusible secteur (temporisé) ............... 15 A
Classe de protection ............................ II
Branchement de l’eau
Température d’arrivée d’eau (max.) . 60 °C

(140 °F)

Débit mini. d’arrivée d’eau (mini.) ... 600 l/h

(2.5 gpm)

Pression d´arrivée (maxi.) ................. 12 bars

(170 psi)

Flexible d’arrivée d’eau .........................
 - longueur (mini.) .............................. 7,5 m

(25 ft)

 - Diamètre (mini.) ............................. 1/2 in
Hauteur d’aspiration depuis un
réservoir ouvert, eau à 20°C(68°F) ..... 1 m

(3 ft)

Caractéristiques de puissance
Pression ............................. 1000-10300 kP
Débit de refoulement ....................... 450 l/h

(1.8 gpm)

Débit d’aspiration de détergent ...... 0-25 l/h

(0-7 gph)

Force de recul au niveau de la poignée-
pistolet,à la pression de service ........ 19 N
Niveau de bruit (DIN 45635) ............. 74 dB (A)
Dimensions
Longueur .......................................... 508 mm

(20 in)

Largeur ............................................. 255 mm

(10 in)

Hauteur ............................................. 284 mm

(11,2 in)

Poids, accessoires compris ............ 15,5 kg

(34 lbs)

Schéma des circuits  électriques

C1 Condensateur de service
F1 Fusible thermique
M1 Moteur
S1 Commutateur de l’appareil
S2 Pressostat

Summary of Contents for 670M

Page 1: ...5 959 533 F65999 01 00...

Page 2: ...D RELIEVE PRESSURE Veuillez lire attentivement la pr sente notice d instructions avant la mise en service et respecter en particulier les Consignes de s curit pour nettoyeurs haute pression 5 951 949...

Page 3: ...e 16 Spray lance with pressure control 17 Dirt blaster 18 Washing brush 1 Poign e de transport 2 Tambour flexible haute pression 3 Sortie haute pression 4 Commutateur MARCHE ARRET 5 C ble de brancheme...

Page 4: ...4 Starting Mise en service...

Page 5: ...5 Operation with high pressure Marche avec haute pression...

Page 6: ...6 A Operation with Detergent B Suction operation A Marche avec un d tergent B Mode aspiration...

Page 7: ...7 A Switching Off B Care and maintenance A Domaine d application B Entretien et maintenance...

Page 8: ...iance and secure the trigger with the safety ratchet against unintentional opening Frost will destroy an appliance which has not been completely emptied of water Troubleshooting Note Disconnect the ap...

Page 9: ...i n a pas t enti rement vidang de son eau Il est re command de ranger l appareil en hiver de pr f rence dans une pi ce l abri du gel Rem des en cas de panne Remarque Retirer la fiche m le de la prise...

Page 10: ...iance switch S2 Pressure operated switch Donn es techniques Branchement lectrique Tension 1 60 Hz 120 V Puissance raccord e 1 5 kW 2 0 hp Fusible secteur temporis 15 A Classe de protection II Branchem...

Page 11: ...34 0 2 883 111 0 5 321 445 0 5 321 445 0 5 029 842 0 6 303 047 0 4 760 440 0 4 762 270 0 6 363 031 4 775 390 0 5 037 140 0 5 332 464 0 6 362 498 0 2 880 296 0 6 390 463 0 KARCHER 4 763 977 0 2 883 111...

Page 12: ......

Reviews: