9
2.4 Putting out of operation
• Switch off the brush drive (Fig. F /3).
• Put the
puzzi
out of operation.
3. Servicing
3.1 After each occasion of use
• Rinse the PW 10 with clean water.
• Remove any fluff and dirt from around the brush.
• Check the spray pattern of the nozzle mouthpiece. If the spray is irregular clean the
nozzle and nozzle mouthpiece.
• If the suction power decreases - Clean the suction hose and suction nozzles.
3.2 Every six months
• Check the toothed belt for wear and tension; replace if necessary.
• Check the brush for wear, replace if necessary.
4. Brush replacement
• Unscrew the 3 nuts and remove the cover (Fig. F /1).
• Remove the toothed belt.
• Unscrew the screw at the end of the brush.
• On the opposite side, remove the mounting plate by unscrewing the two screws and
remove the brush (Fig. F /2).
• Fit the new brush in the reverse order.
If the brush has been blocked so that the motor has switched itself off.
Remedy:
•
Switch off the brush drive motor (Fig. F /3).
•
Check the brush for contamination and remove any object that may have
prevented its rotation.
•
Unscrew the protective cap and press in the safety switch with the blade of
a screwdriver (Fig. F /4).
•
Then screw the cap back in place.
Fig. F
ENGLISH