OPERATING INSTRUCTIONS
Working in Automatic mode (self-leveling):
In automatic mode the laser level, will level itself in a ±2.5° range
and can project 1 horizontal ,4 vertical lines and 1 plumb dot.
These lines will create 1 cross line on the wall and a second
cross line on the ceiling.
1. Remove the laser from the case and place it on a flat, vibration
free surface or on a tripod.
2. Adjust the unit’s support legs (#6), or the tripod legs, until the
surface level (#4) is centered.
3. Turn the pendulum safety lock (#11) clockwise, to the
ON
position. The surface level at the center of the keypad (#4)
will light up and the forward cross beam and plumb dot will be projected.
4. To direct the beams to the desired position, turn the laser and
use the fine – adjustment knob (#5) for precise positioning.
5. Press the V button (#2) and the rear vertical beam will also be
projected.
6. An additional click on the V button (#2) will project the additional
2 side vertical beams creating an additional cross beam above
the laser.
7. One more click on the
V
button (#2) will turn off all the vertical
beams at once.
8. Press the
H
button (#1) to turn the horizontal beam on or off.
9. If the initial level of the laser is beyond ± 2.5°, the laser beams
will flash and a beeping alarm will be heard. In this case
reposition the laser on a more leveled surface.
10. Before moving the laser level, turn the pendulum safety
lock (#11) counterclockwise to the
OFF
position. This will lock
the pendulum and protect your laser.