background image

13

GB

NOISE AND VIBRATIONS

Measured values determined according to EN60745
lpa: 94dB (A)
wpa: 105dB (A)
k:3dB (A)

WEAR EAR PROTECTIONS!

VIBRATIONS

Measured values determined according to  EN60745
ah:3,06m/s2
k:1,5m/s2

GENERAL SAFETY INSTRUCTIONS

1) keep the work area clean; unclean work areas increase the risk of accidents
2) use caution around the work area: do not expose the machine to rain do not use the machine in humid places or where there is 
water keep work areas well lit do not use the machine in the presence of flammable liquids or gases 
3) be watchful for the risk of electrical shock avoid bodily contact with surfaces that might act as earthing elements (pipes, radiators, 
other metallic parts) 
4) keep others far away from the machine do not allow other persons, particularly children, to touch the machine or power cable 
even unintentionally 
5) store safely when the machine is not being used it should be kept in a dry place out of children’s reach 
6) do not force the machine the machine will work better if it does not work under stress 
7) use the appropriate machine for the type of work to be done do not force small machines to do the work of more powerful machines 
do not use machines to do jobs that are different from the ones they were designed to do 
8) wear suitable work clothes do not wear loose clothes or jewelery that could become entangled in moving parts insulated safety 
shoes are recommended wear a cap or hat to keep long hair out of the way always wear proper protective equipment wear safety 
glasses while working, respiratory protective equipment that is certified according to standard EN149 must obligatorily be wornB
9) keep the power cable in good condition. do not pull the power cable to disconnect it from the socket keep the cable away from 
oils, heat sources or sharp surfaces 
10) maintain a proper safety position while working work in a balanced position, standing on both feet
11) store the machine carefully keep cutting surfaces sharp follow instructions for lubricating and spare parts inspect the power 
cable periodically and if damaged have it repaired by an authorised service centre keep the machine and particularly the handles 
clean and free of oil or grease 
12) unplug the machine always unplug the machine from the mains power supply when it is not in use and when spare parts or 
diamond discs are assembled or replaced
13) remove wrenches and other tools from the machine before starting up the machine, always check that wrenches or other tools 
used for adjustments have not been left on it 
14) avoid starting up the machine unintentionally ensure that the power switch is in the OFF position before plugging in the power 
cable
15) use extensions for outdoor use if the machine is used outdoors, use only electric extensions suitable for outdoor use
16) be very attentive always be aware of what you are doing while the machine is functioning; do not use the machine when under 
the effects of drugs or alcohol or when you are tired 
17) check damaged parts before using the machine each time, check the components to make sure the machine is intact check 
the alignment of moving parts, check for loose bolts or screws or other parts that may jeopardize the correct use of the machine 
replace damaged protective devices immediately at an authorized service centre; do not use the machine without protective devices 
if the switch is damaged, replace it immediately at an authorized service centre; do not use the machine if the switch is not in good 
condition do not use the machine if the switch does not function correctly; contact an authorized service centre

Summary of Contents for GIGAM KME 1200

Page 1: ...Art 38623 KME 1200 Leggere attentamente le istruzioni contenute nel presente manuale prima dell utilizzo Conservare il manuale come riferimento futuro...

Page 2: ...i a cura della Morganti S p A presso il CENTRO ASSISTENZA di Lecco secondo i termini e le modalit riportati nella docu mentazione allegata ai prodotti stessi A tal fine si raccomanda di conservare la...

Page 3: ...nsabilit che la macchina KME 1200 art 38623 descritta nella documentazione allegata realizzata in conformit ai requisiti della Normativa Macchine 98 37 EC EN60745 1 2006 EN60745 2 1 A11 2007 Nota ques...

Page 4: ...si utilizza la macchina metterla al riparo in un luogo asciutto fuori dalla portata dei bambini 6 non forzare la macchina la macchina lavorer meglio se non viene portata sotto sforzo 7 utilizzare la m...

Page 5: ...ool o quando si stanchi 17 controllare le parti danneggiate prima di ogni uso della macchina controllare i componenti per verificare l integrit della macchina stessa controllare l allineamento delle p...

Page 6: ...Manopola per il cambio marcia 2 Interruttore 3 Pulsante di Bloccaggio dell interruttore 4 Aperture di ventilazione 5 Albero con filetto M14 femmina 6 Frusta di miscelazione 7 Rotella di variazione del...

Page 7: ...senza solventi o sostanze simili In caso di utilizzo non conforme rispetto a quanto riportato sopra ogni responsabilit decade diretta mente sull utilizzatore e la garanzia viene considerata non valid...

Page 8: ...un risultato uniforme Al termine del lavoro staccare la macchina dalla presa di corrente e pulire la frusta di miscelazione per evitare incrostazioni SOFT START ELETTRONICO La macchina dotata di un s...

Page 9: ...Utilizzare un cacciavite a testa piatta per svitare I due porta spazzole 8 rimuovere le spazzole usurate e sostituirle entrambe con un paio nuove chiudere nuovamente ed avvitare I porta spazzole 8 IND...

Page 10: ...09 IT...

Page 11: ...ngranaggio doppio 28 cuscinetto 29 dado 30 diaframma 32 rondella 33 cuscinetto 34 rotore 35 isolamento 36 cuscinetto 37 cuscinetto 38 seger 39 ingranaggio 40 tappo olio 41 vite 42 chiavetta 43 alberin...

Page 12: ...d conditions specified in the documents attached to the products We therefore recommend that you keep the INVOICE or the SALES RECEIPT bearing the date of pur chase the model and serial number data th...

Page 13: ...i s p a via S Egidio 12 23900 Lecco Italy solemnly declares that the machine KME 1200 art 38623 described in the attached document complies with the requisites regarding the Regulation of Machines 98...

Page 14: ...the power cable to disconnect it from the socket keep the cable away from oils heat sources or sharp surfaces 10 maintain a proper safety position while working work in a balanced position standing on...

Page 15: ...d become damaged and not function correctly do not use diamond discs that are not sharp or that are bent or damaged always use proper respiratory protective equipment to avoid breathing dangerous dust...

Page 16: ...ree paints varnish and similar substances The user alone is responsible for any liabilities caused by usage other than intended PRE START INSPECTIONS The following Pre start up inspection must be perf...

Page 17: ...al has been mixed Once the mixing process has been completed clean the mixing paddle 6 to stop the build up of dirt and residue STARTING CURRENT LIMITING The electronically controlled soft start ensur...

Page 18: ...HE CARBON MOTOR BRUSHES Also keep the ventilation slits 4 clear of dirt and residue so that the machine can be cooled adequately Note The numbers shown in brackets refer to the pictures shown in the M...

Page 19: ...18 GB...

Page 20: ...27 Spindle double gear 28 Bearing 699 ZZ 29 Nut M8 30 Gear box 32 Felted wool 33 Bearing 6000 2RS 34 Aemature Ass y 35 Insulating mat 36 Bearing 608ZZ 37 Bearing 608ZZ NO Description 38 Safety ring 39...

Page 21: ...r parateurs agr s par Morganti spa pr sents sur le territoire selon les termes et les modalit s report s dans la documentation jointe auxdits produits cet effet on recommande de conserver la FACTURE o...

Page 22: ...gidio 12 23900 Lecco Italy d clare sous sa responsabilit que la machine KME 1200 art 38623 qui est d crite dans la documentation ci joint est conforme aux exigences de la Directive relative aux Machi...

Page 23: ...s elles ont t r alis es 8 porter des v tements appropri s ne pas porter de v tements vas s et des bijoux qui pourraient se coincer dans les parties en mouvement il est conseill de porter des chaussure...

Page 24: ...istance agr ne pas utiliser la machine si l interrupteur n est pas en bon tat ne pas utiliser la machine si l interrupteur ne fonctionne pas correctement s adresser un centre d assistance agr 18 ne pa...

Page 25: ...rnis sans solvants ou substances similaires En cas d utilisation non conforme par rapport ce qui est report ci dessus toute responsabilit tombera directement sur l utilisateur et la garantie ne s appl...

Page 26: ...e la fin du travail d brancher la machine de la prise de courant et nettoyer le fouet de malaxage pour viter les incrustations D MARRAGE LECTRONIQUE EN DOUCEUR La machine est quip e d un d marrage en...

Page 27: ...ement le fonctionnement en cas de consommation excessive des brosses REMPLACEMENT DES BROSSES Les trous d a ration doivent toujours tre propres ceci permet d allonger la dur e de vie des brosses 1 uti...

Page 28: ...s por el SpA Morganti En el centro de Lecco o en otro servicio t cnico autorizado spa Morgati en la zona de acuerdo con los t rminos y condiciones establecidos en la documentaci n que acompa a a los p...

Page 29: ...S Egidio 12 23900 Lecco Italy declara bajo su responsabilidad que la m quina KME 1200 art 38623 que se describe en la documentaci n que se adjunta es conforme con los requisitos de la Directivas de M...

Page 30: ...o use ropa suelta o joyas que puedan quedar atrapados en las piezas m viles se recomiendan zapatos de seguridad aislados usando un auricular o un sombrero para recoger el pelo largo llevar equipo de p...

Page 31: ...est en buenas condiciones no utilice la m quina si el interruptor no funciona correctamente p ngase en contacto con un centro de servicio autorizado 18 No use accesorios o piezas no aprobados por el...

Page 32: ...res USO DE LA M QUINA La m quina est dise ada para materiales de construcci n como el mortero de mezcla en polvo yesos colas pinturas sin disolventes o sustancias similares En caso de uso indebido de...

Page 33: ...erial de trabajo se recomienda hacer girar en vac o durante unos segundos para que se enfr e el motor de la m quina m s r pido Durante la mezcla mover lentamente la varilla a lo largo de todo el per m...

Page 34: ...antenimiento solo con la maquina desconectada Mantenimineto ordinario 75 horas aprox 150 horas aprox escobillas Control nivel sustituci n Grasa caja de cambio Control sustituci n debe de realizarlo pe...

Page 35: ...www kapriol com...

Page 36: ...1 215411 fax 39 0341 215400 www kapriol com e mail kapriol kapriol com Made in P R C KME 1200 Art 38623 Nr di serie MORGANTI SPA Via S Egidio 12 23900 LECCO Registro delle Imprese di Lecco N iscr C F...

Reviews: