background image

USER MANUAL

MODEL:

   

ECMR-250

           Dimmer module receiver 

FEATURE:

Self program, 67 million codes.
ON/OFF/DIMMER function.
Suitable only for lights, 230V incandescent or halogen
lamp.
Connect with (non-dimmable) electronic transformer for 12V halogen lamp.
Not suitable for traditional transformer.
6 memories for scene setting.
Green LED indication.
Compatible to all KAPPA transmitters.
Standby power consumption: 1 W.

INSTALLATION: 

(Fig. 1)

- Disconnect main power line.
- Connect LIVE AC 230V wire to ECMR-250 port L

- Connect LIVE lamp wire to ECMR-

250 port

- Connect Neutral AC 230V wire to lamp. 
- Turn on main power line.
- LED indicator light on and load light on.

HOW TO SET / DELETE CODE WITH KAPPA
TRANSMITTER:
SET (LEARN) CODE:

 (Fig. 2)

- After correct installation, switch on the main power.
- Bring the transmitter near the receiver, push the self

program button on receiver once.

- Receiver LED will blink slowly, press transmitter

selected “ON” button.

- Receiver connected lamp will blink twice, code is

confirmed and LED stops blinking.
(Remember the transmitter button you selected for
the programmed receiver.)

- Transmitter and receiver code is auto programmed.
- Same procedure to link with KAPPA code switch

transmitter.

Summary of Contents for ECMR-250

Page 1: ...port L Connect LIVE lamp wire to ECMR 250 port Connect Neutral AC 230V wire to lamp Turn on main power line LED indicator light on and load light on HOW TO SET DELETE CODE WITH KAPPA TRANSMITTER SET LEARN CODE Fig 2 After correct installation switch on the main power Bring the transmitter near the receiver push the self program button on receiver once Receiver LED will blink slowly press transmitt...

Page 2: ...Switch ON function press ON button once z Switch OFF function press OFF button once z DIMMING function press ON button first time to switch on then press a second time ON button start to dim When light reaches wanted brightness level press ON button again to stop dimming If not manual to stop dimming after light running up down 4 cycles ECMR 250 will automatically stops dimming at last selected br...

Page 3: ...rammed memory and Receiver 2 only 2 program memory Different combinations and settings can be teamed up and controlled from transmitter SPECIFICATION Frequency 433 92 MHz Power 230V 10 50Hz Output 40 W VA 250 W 210 VA Transmission distance 50 meter open field Load type Incandescent lamp high voltage 230V and halogen lamp high voltage 230V Electronic transformer non dimmable for halogen lamp low vo...

Page 4: ...mable liquid solvents paints etc Do not use with fluorescent or compact fluorescent lamps CFL Do not use with traditional transformers conventional wire wound or toroidal transformers Do not use with electric motors Wrong application of traditional transformers conventional wire wound or toroidal transformers will cause ECMR 250 out of function eg Fig 7 ...

Reviews: