KANE455
manual
Page
22
5. USING
THE
MENU
Select “Menu” on the rotary switch and navigate using the function buttons:
= Scroll up
= Scroll down
= Enter
MAIN
MENU
SUB MENU OPTIONS / COMMENTS
SETUP SET
FUEL
NAT GAS, L OIL, PROPANE, BUTANE, LPG
KANE455 always defaults to Nat Gas on start-
up
N
C
G
Ef(C) = condensing boilers
Ef(N) = nett efficiency, Ef(G) = gross efficiency,
KANE455 always defaults to EfC on start-up
SET
TIME
HH:MM:SS format
e.g. 7 am = 07:00:00, 7pm = 19:00:00
SET
DATE
DD/MM/YY
format
EXIT
PRESSURE SMOOTH
OFF = normal response. ON = slower (damped)
response
KANE455 always defaults to normal response
on start-up
RESOLVE
LOW = e.g. 0.01mBar resolution. HIGH =
displays to an extra decimal place.
KANE455 always defaults to low resolution on
start-up
PS
UNITS
mBar, mmH
2
O, Pa, kPa, PSI, mmHg, hPa, InH
2
O
KANE455 always defaults to mBar on start-up
TIME
LET BY = Set duration of let-by test in minutes.
Default = 1 minute
STABIL’N = Set duration of stabilisation in
minutes. Default = 1 minute
TIGHTN’S = Set duration of tightness test in
minutes. Default = 2 minute
EXIT