Ranges

Accuracy

Resolution

Overload Protection

600Ω to 6MΩ

±(0.8% +5 dgts)

0.1Ω to 0.001MΩ

600V

40MΩ

±(1.5% +5 dgts)

0.01MΩ

Features:  

RANGE

 

MIN/MAX

 

HOLD

 

 

 

 

WARNING

  Do not measure resistance on a live circuit.

Resistance: <40MΩ

Open Circuit Voltage

Audible Threshold

Overload Protection

Approx.: <1.0V

Approx.: 40Ω

600V

Features:  

MIN/MAX

 

HOLD

 

 

• Bu

zzer sounds at less than 40Ω.

 

 

WARNING

• Do no

t measure resistance on a live circuit.

Continuity

RANGE

SEL

Temp

A

True RMS

MIN/MAX

HOLD

FAST

V

Apo

µA

mAµA

A

mA

  10A

MAX

FUSED

  400mA

MAX

FUSED

MAX

CAT III

600V

CAT II

1000V

DM515

°F°C

µA

A

mA

°F°C

Apo

AT

RANGE

SEL

MIN/MAX

HOLD

FAST

V

Apo

A

µA

mAµA

A

mA

  10A

MAX

FUSED

  400mA

MAX

FUSED

MAX

CAT III

600V

CAT II

1000V

DM505

µA

A

mA

°F°C

Apo

KANE515

®

KANE515

®

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 515

Page 1: ...V Apo A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V F C INSTRUCTION MANUAL ENGLISH True RMS 1000V Digital Multimeter w Temperature 1000V CAT II 600V CAT III KANE515 KANE515...

Page 2: ...OVERVIEW 5 SYMBOLS 6 OPERATING INSTRUCTIONS AC DC Voltage 1000V AC DC 6 Resistance 40M 7 Continuity 7 Diode 8 Capacitance 8 9 AC DC Milliamps 400mA 9 AC DC Amps 10A 10 Temperature C F 10 Test Lead Not...

Page 3: ...Backlight Yes Over range OL is displayed Dimensions 6 50 x 3 31 x 2 28 Item Weight 15 2 oz Calibration Recommended annually CAT Rating CAT III 600V CAT II 1000V Certifications Battery Type AA 2 Test L...

Page 4: ...injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current path Even small amounts of current can...

Page 5: ...readings E Select Button Press to select AC DC or Auto Selection in the Press to select C or F in the Temperature function F Function Dial Turns on meter and is used to select the function G Hold Fas...

Page 6: ...e common or multifunction input ports as measured from earth ground Features RANGE MIN MAX HOLD SEL RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT...

Page 7: ...0V Approx 40 600V Features MIN MAX HOLD Buzzer sounds at less than 40 WARNING Do not measure resistance on a live circuit Continuity RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A mA 10A...

Page 8: ...mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 F C A A mA F C Apo V Forward Bias Displays approx voltage drop RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A m...

Page 9: ...ast Fuse Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Resolution Overload Protection 60mA to 400mA 1 0 3 dgts 0 01mA to 0 1mA 600mA 1000V Fast Fuse Minimum sensitivity 5mA...

Page 10: ...CAUTION 20A overload for 30 seconds max F Ranges Accuracy Resolution Overload Protection 328 to 999 F 1 5 3 6 F 0 1 F 600V 1000 to 2462 F 1 5 3 0 F 1 F C Ranges Accuracy Resolution Overload Protection...

Page 11: ...ed conductors such as standard wall outlets Take care not to lose the shields WARNING Test lead category protections apply only to test leads and should not be confused with the meter s specific CAT r...

Page 12: ...f the FCC Rules and CAN ICES 3 A Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including...

Reviews: