Kane 515 Instruction Manual Download Page 3

3

FUNCTIONS

FEATURES

  1000V AC/DC

  10A AC/DC

  Resistance 40MΩ

  Diode test

  Audible continuity

  Capacitance 9999µF

  Temperature -328˚ to 2462˚F (-200˚ to 1350˚C)

  Microamps

  Milliamps

  Auto/Manual ranging

  True RMS

  Auto power off

  Min/Max

  Hold

  1 ms Fast response Min/Max

  Low battery indicator

  Rubber boot

  Test lead holders

  Kick stand

  High resolution backlit display

  Fused test lead inputs

   Auto selection

GENERAL SPECIFICATIONS

• 

  Operating Temperature: 

32˚ to 122˚F (0˚ to 50˚C)

• 

  Storage Temperature: -

44˚ to 122˚F (-20˚ to 50˚C)

• 

  Operating Humidity: 

<75% max.

• 

  Operating Altitude: 

6561 ft (2000m)

• 

  Display: 

6,000 

• 

  Backlight: 

Yes

• 

  Over-range: 

“OL” is displayed

• 

  Dimensions: 

6.50” x 3.31”x 2.28” 

• 

  Item Weight: 

15.2 oz

• 

  Calibration: 

Recommended annually

• 

  CAT Rating: 

CAT III 600V/CAT II 1000V

• 

  Certifications: 

• 

  Battery Type: 

(AA) 2

• 

  Test Leads: 

CAT III test leads

• 

  Accuracy: 

± (% of r # of least significant digits)

Measurement Category

Short-Circuit (typical) kA

a

Location in the building installation

II

< 10

Circuits connected to mains socket outlets and similar 

points in the MAINS installation

III

< 50

Mains distributions parts of the building

IV

> 50

Source of the mains installation in the building

CATEGORY DEFINITIONS

cETLus UL 61010-1:2012 3rd

CE EN 61010-1:2010 3rd, IEC61010-2-033:2012 Ed.1, EN 61326-1:2013

FCC, RoHS Compliant, TOV protection, IP 42. 6’ Drop protection

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 515

Page 1: ...V Apo A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V F C INSTRUCTION MANUAL ENGLISH True RMS 1000V Digital Multimeter w Temperature 1000V CAT II 600V CAT III KANE515 KANE515...

Page 2: ...OVERVIEW 5 SYMBOLS 6 OPERATING INSTRUCTIONS AC DC Voltage 1000V AC DC 6 Resistance 40M 7 Continuity 7 Diode 8 Capacitance 8 9 AC DC Milliamps 400mA 9 AC DC Amps 10A 10 Temperature C F 10 Test Lead Not...

Page 3: ...Backlight Yes Over range OL is displayed Dimensions 6 50 x 3 31 x 2 28 Item Weight 15 2 oz Calibration Recommended annually CAT Rating CAT III 600V CAT II 1000V Certifications Battery Type AA 2 Test L...

Page 4: ...injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current path Even small amounts of current can...

Page 5: ...readings E Select Button Press to select AC DC or Auto Selection in the Press to select C or F in the Temperature function F Function Dial Turns on meter and is used to select the function G Hold Fas...

Page 6: ...e common or multifunction input ports as measured from earth ground Features RANGE MIN MAX HOLD SEL RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT...

Page 7: ...0V Approx 40 600V Features MIN MAX HOLD Buzzer sounds at less than 40 WARNING Do not measure resistance on a live circuit Continuity RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A mA 10A...

Page 8: ...mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM515 F C A A mA F C Apo V Forward Bias Displays approx voltage drop RANGE SEL Temp A True RMS MIN MAX HOLD FAST V Apo A mA A A m...

Page 9: ...ast Fuse Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Resolution Overload Protection 60mA to 400mA 1 0 3 dgts 0 01mA to 0 1mA 600mA 1000V Fast Fuse Minimum sensitivity 5mA...

Page 10: ...CAUTION 20A overload for 30 seconds max F Ranges Accuracy Resolution Overload Protection 328 to 999 F 1 5 3 6 F 0 1 F 600V 1000 to 2462 F 1 5 3 0 F 1 F C Ranges Accuracy Resolution Overload Protection...

Page 11: ...ed conductors such as standard wall outlets Take care not to lose the shields WARNING Test lead category protections apply only to test leads and should not be confused with the meter s specific CAT r...

Page 12: ...f the FCC Rules and CAN ICES 3 A Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including...

Reviews: