OVERVIEW

RANGE

SEL

MIN/MAX

HOLD

FAST

V

Apo

A

µA

mAµA

A

mA

  10A

MAX

FUSED

  

400mA

MAX

FUSED

MAX

CAT III

600V

CAT II

1000V

B

A

C

H

J

K

L

N
O

I

E

F

G

D

A.  Apo

: Auto power off after 30 minutes of use. Press

  and hold the HOLD button while turning the meter on

  to disable Apo

.

B.  Digital Backlit Display 

C.  Range Button: 

 

  Press to change from auto ranging to manual ranging.

 

  Press repeatedly to select proper range.

 

  Press and hold to return to auto range (AT will be  

    displayed on screen).

D.  Min/Max Button:

 

  Press to enter MAX/MIN mode.

 

  In the V, µA, mA or Amps functions, either select AC/ 

    DC or change to manual ranging before pressing this  

    button to enter MAX/MIN mode.

 

  Press repeatedly to alternate between Maximum and  

    Minimum readings.

 

  Press and hold to return to live readings

E.  Select Button:

 Press to select AC,DC or Auto Selection  

  in the following functions: Voltage, µA, mA, Amps. 

F.  Function Dial:

 Turns on meter and is used to select  

  the function. 

G.  Category Max Indicator:

 Maximum CAT Rating for  

  fused input jacks.     

 

  Multifunction input port used for measuring: AC or DC  

    volts, resistance, continuity, diode, Amps, mA, µA.

 

  Use CATIII test leads or higher.  

H.  Hold/Fast Button: 

 

  Press to hold the reading on the display. Press again  

    to return to live reading.

 

  Press to enter Fast MAX/MIN mode in MAX/MIN mode.

 

  Press again to return to normal MAX/MIN mode. 

I.  Back Light Button:

 Press to on back light. Press again  

  to turn off. Back light duration is 1 minute. 

J.  Recess for magnetic hanger

K.  Test Lead Holders

L.  Protective Rubber Boot

M. Battery Cover (under protective rubber boot) 

N.  Kick Stand

O.  Serial Number (under kick stand)

M

KANE505

®

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for 505

Page 1: ...FAST V Apo A A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V INSTRUCTION MANUAL ENGLISH 1000V CAT II 600V CAT III KANE505 1000V Digital Multimeter KANE505 www com information...

Page 2: ...BOLS 6 OPERATING INSTRUCTIONS AC DC Voltage 1000V AC DC 6 Resistance 40M 7 Continuity 7 Diode 8 Capacitance 8 AC DC Microamps 6000 A 9 AC DC Milliamps 400mA 9 AC DC Amps 10A 10 Test Lead Notes 10 Batt...

Page 3: ...ge OL is displayed Dimensions 6 50 x 3 31 x 2 28 Item Weight 15 2 oz Calibration Recommended annually CAT Rating CAT III 600V CAT II 1000V Certifications cETLus UL 61010 1 2012 3rd CE EN 61010 1 2010...

Page 4: ...ys adhere to national and local safety codes Use proper personal protective equipment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a c...

Page 5: ...ress and hold to return to live readings E Select Button Press to select AC DC or Auto Selection in the following functions Voltage A mA Amps F Function Dial Turns on meter and is used to select the f...

Page 6: ...s DC RMS at either the common or multifunction input ports as measured from earth ground Features RANGE MIN MAX HOLD SEL RANGE SEL MIN MAX HOLD FAST V Apo A A mA A A mA 10A MAX FUSED 400mA MAX FUSED M...

Page 7: ...tion Approx 1 0V Approx 40 600V Features MIN MAX HOLD Buzzer sounds at less than 40 WARNING Do not measure resistance on a live circuit Continuity RANGE SEL MIN MAX HOLD FAST V Apo A A mA A A mA 10A M...

Page 8: ...voltage drop Features RANGE MIN MAX HOLD AC VOLTS Ranges Accuracy Resolution Overload Protection 10nF to 9999 F 3 0 5 dgts 0 01nF to 1 F 600V Capacitance RANGE SEL MIN MAX HOLD FAST V Apo A A mA A A...

Page 9: ...2 5 dgts 0 01mA to 0 1mA 600mA 1000V Fast Fuse Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Resolution Overload Protection 60mA to 400mA 1 0 3 dgts 0 01mA to 0 1mA 600mA 10...

Page 10: ...mA A Apo AT A Test Lead Notes CATIII 1000V Measurement Locations Ensure the test lead shield is pressed firmly in place Failure to use the CATIV shield increases arc flash risk CATII 1000V Measurement...

Page 11: ...communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can...

Page 12: ...age expenses or economic loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when re...

Reviews: