14 KANE 358 MANUAL

STATUS BAR ICONS

Icons give quick & simple status information:

STATUS BAR ICON LEVEL 

Pump status On or Off

Analyser has logged/

stored data

Battery Status indication

Data being sent to App or

Printer

ICON LIST

PUMP

LOGGED DATA

SENDING DATA

BATTERY

Summary of Contents for 358

Page 1: ...KANE 358 Flue Gas Analyser with direct O2 measurement and CO sensor protection Stock No MAN00164 Rev 1 00321 MARCH 2021 Kane International Ltd...

Page 2: ...ATE 9 CHARGING NIMH BATTERIES 9 BATTERY DISPOSAL 9 GENERAL SAFETY 10 FIRST TIME USE 11 GENERAL OPERATING PRINCIPLE 11 15 QUICK START 11 USER INTERFACE 11 STATUS 12 STATUS BAR 12 STATUS BAR LAYOUT 13 S...

Page 3: ...W MENU OPTIONS 21 NAVIGATING STORED REPORTS 22 REPORT NAVIGATION MENU OPTIONS 22 PRESSURE TEMPERATURE TESTING 23 TEMPERATURE PRESSURE DISPLAY 23 VIEWING SENDING PRINTING 23 PRESSURE MEASUREMENT GOOD P...

Page 4: ...ensor Your KANE358 has a low gas flow detector that switches off the analyser s pump if it detects water entering the analyser from an overfilled water trap Your KANE358 has a large 6 line display sho...

Page 5: ...5 KANE 358 MANUAL ANALYSER FEATURES AND KEYPAD...

Page 6: ...ers a print destination when both wireless and irda fitted Navigate up Short press to scroll up Enter button Used to select the current option Navigate down Short press to scroll down Data hold Short...

Page 7: ...temperature T2 Pressure connection P1 Pressure connection P2 Differential Flue gas inlet On Off Function buttons see below Water trap particle filter Rotary switch Red connector plugs into Flue Gas I...

Page 8: ...8 KANE 358 MANUAL Watertrap drain with red plug Thermocouple Thermocouple Wire Stainless Steel Shaft Depth Stop Cone Gas Path Magnets x2...

Page 9: ...ring they are fitted with correct battery polarity Replace battery cover protective rubber cover TIME AND DATE After changing batteries reset your analyser s time date CHARGING NIMH BATTERIES Your KAN...

Page 10: ...to known gas mixtures to change the output of all sensors present Note This is different from a calibration where the instrument is also exposed to known gas mixtures but allowed to settle to a steady...

Page 11: ...ENERAL OPERATING PRINCIPLE Using your KANE358 is simple with the rotary dial and user interface Most tests can be made with little user activity Your analyser s status bar offers options based on task...

Page 12: ...bar No of days until next calibration due Status bar Current fuel selection use status bar menu to change fuel selection STATUS BAR The Status bar shows instrument status and offers options based on y...

Page 13: ...AREA Display alternates between Hold symbol time stamp of held data Displays current time CALIBRATION DUE WARNING MESSAGE AIR PURGE SNOOZE TIMER LOW BATTERY WARNING MESSAGE Display alternates between...

Page 14: ...CONS Icons give quick simple status information STATUS BAR ICON LEVEL Pump status On or Off Analyser has logged stored data Battery Status indication Data being sent to App or Printer ICON LIST PUMP L...

Page 15: ...n the items displayed on the screen STANDARD OPTIONS Date Displays selected fuel type To change long press button to display selection indicators Press or buttons to select fuel then press button Turn...

Page 16: ...s to your requirements Navigate through the Menu system using these buttons Menu option to edit As you navigate up or down through the menu items will move up or down the screen returning to the begin...

Page 17: ...PE IR PRINT Select KMIRP IRP 2 02 REF 02 REF Use for Normalised readings Default set to 3 can adjust up or down LANGUAGE LANG Selects your required language CODE CODE Password protected for authorised...

Page 18: ...r become dirty and blocked View displayed data to ensure stable operating conditions are achieved and readings are within expected range PRINTING To print simply press and release the button Select yo...

Page 19: ...THE AUX SCREEN You can customise lines 1 to 5 of the AUX screen To edit a line press until EDIT appears on the status bar Press and hold to select EDIT The cursor flashes and the line number appears i...

Page 20: ...displays when your analyser has stored data To view current memory turn rotary dial to MENU then select LOGS to display this CO CO2 reading Carbon Monoxide reading Carbon Dioxide reading Excess Air re...

Page 21: ...g press button List of available logs Navigate select using Buttons Return to main menu MENU OPTIONS VIEWING STORED REPORTS To view your reports select VIEW option from REPORTS Menu REPORT VIEW MENU O...

Page 22: ...port type Navigation menu options Report number of that type NAVIGATING STORED REPORTS Once you select your report the first report is displayed REPORT NAVIGATION MENU OPTIONS Prints currently selecte...

Page 23: ...at 80 mbar with a maximum over range of 400 mbar Rotate the dial to Prs Temp and use the black connectors manometer hose to connect to P1 for single pressure or P1 P2 for differential pressure VIEWIN...

Page 24: ...ied limits LARGE BORE TUBING ISSUES If using large bore tubing when performing pressure tests Push orange tube over rim of spigot to ensure a gas tight seal This may not produce a gas tight seal COMMI...

Page 25: ...50ppm RATIO under 0 0040 TEST 3 CHECK THE APPLIANCE AT MINIMUM GAS FLOW RATE WHERE THIS IS POSSIBLE Once the appliance is stable at its minimum gas rate measure CO CO RATIO levels these must be within...

Page 26: ...then press to start the let by test display shows If let by test fails rotate dial to another position to stop the test If Let by test passes adjust gas pressure for the tightness test press to start...

Page 27: ...ins how to view print stored reports Tightness test is automatically stored in the memory Pressure at start of tightness test Real time pressure reading Tightness default time is 120 seconds can be ch...

Page 28: ...28 KANE 358 MANUAL PRINTOUTS Auxiliary Tightness Combustion Pressure Temp Commission...

Page 29: ...ral Gas Light Oil Bio Oil Coke LPG Wood Town Gas Butane Propane Battery Life 8 hours continuous with pump on Certification The KANE358 is independently tested and certified to EN 50379 Parts 1 3 in ac...

Page 30: ...NUAL Operating Conditions Temperatures 0 45 C Humidity 15 to 90 RH non condensing Power Supply Rechargeable batteries USB Charging Physical Characteristics Weight Approx 0 625g Dimensions L 216mm x H...

Page 31: ...01165EU Restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS The following harmonised standards and technical specifications have been applied CERTIFICATI...

Page 32: ...cked into the analyser as their sensors can become blocked with water stopping them see flue gases When this happens Oxygen or Carbon Dioxide reading will display as sensors may be permanently damaged...

Page 33: ...33 KANE 358 MANUAL THIS PRODUCT CONFORMS WITH THE FOLLOWING PLEASE RECYCLE MADE IN THE UK sales norrscope com...

Reviews: