K&S BASIC KSB 40i S Owner'S Manual Download Page 5

WORKING WITH THE DEVICE

5

  

  

OIL LEVEL INDICATOR

OIL LEVEL INDICATOR

When the oil level falls below the level required for operation, the oil level indicator lights up, and then the engine 

stops automatically. The engine will not start until oil is added.

  

  

OVERLOAD INDICATOR

OVERLOAD INDICATOR

The overload indicator lights up when the connected generator is overloaded, the inverter control unit overheats or 

the AC output voltage rises.
If the overload indicator goes on, the engine will continue to operate, but the generator will no longer produce 

electricity. In this case, you must perform the following steps:

Make sure the control panel, louver and the inverter bottom 

side cooling well and without chips, mud and water come in. It 

may damage the engine, inverter or alternator if the cooling vent 

blocked.

IMPORTANT!

  

  AC 

AC 

INDICATOR

INDICATOR

When the generator is running and producing electricity, the AC indicator light is on.

  

  

DC PROTECTOR

DC PROTECTOR

The DC protector turns to “OFF” automatically when electric device being connected to the generator is operating 

and current above the rated flows. To use this equipment again, turn on DC protector by pressing its button to “ON”.

Reduce the load of the connected electric device below the 

specified rated output of the generator if the DC protector turns 

off. If the DC protector turns off again, stop using the device 

immediately and contact the point of sale and contact your 

nearest 

K&S Basic TM

 Service Center.

IMPORTANT!

When the overload indicator light comes on and power generation stops, proceed as follows:

1. Turn off any connected electric devices and stop the engine.

2. Reduce the total wattage of connected appliance into the rated output.

3. Check for blockages in the cooling air inlet and around the control unit. If any blockages are found, remove.

4. After checking, restart the engine.

The overload indicator may light up within several seconds after 

start-up or when connecting electrical devices requiring a high 

starting current, such as a compressor or voltage indicator. How-

ever, this is not a malfunction.

IMPORTANT!

  

  

EARTHING BOLT

EARTHING BOLT

In all cases, except for an IT system with an insulated neutral wire and bonding, the generator earthing bolt must 

be connected to the grounding circuit with a flexible copper conductor with a cross-sectional area of at least 6 mm

2

.

BEFORE STARTING

6

  

  

CHECK THE FUEL LEVEL

CHECK THE FUEL LEVEL

1. Unscrew the fuel cap and check the fuel level in the tank.

2. Fill the fuel tank to the fuel filter level.

3. Tighten the fuel cap securely.

www.ks-power.de/en

   

|

    4

Summary of Contents for KSB 40i S

Page 1: ...Please read this manual carefully before use OWNER S MANUAL Inverter Generator KSB 40i S EN...

Page 2: ...he environment therefore we consider it expedient to savepaper and leave in print a short description of the most important sections leave in print a short description of the most important sections F...

Page 3: ...generator if you are tired under the influence of drugs or alcohol Inattention may cause a serious injury ATTENTION DANGER 1 Carrying handles 2 Fuel level indicator 3 Fuel tank cap 4 Fuel filter 5 Wh...

Page 4: ...e long service life of the generator continuous loads of more than 80 of the nominal power are not recommended Model KSB 40i S Voltage V 230 Max Power kW 3 9 Nominal Power kW 3 5 Frequency Hz 50 Curre...

Page 5: ...duce the load of the connected electric device below the specified rated output of the generator if the DC protector turns off If the DC protector turns off again stop using the device immediately and...

Page 6: ...controller settings in terms of the amount of fuel or speed governor this adjustment was made at the factory Otherwise this may result in changes in the engine operation or its failure IMPORTANT In th...

Page 7: ...NT Do not connect two or more devices at a time The start up of many devices requires high power Devices should be connected one at a time according to their power rating Do not connect any power cons...

Page 8: ...sconnect all devices connected to the generator then disable the ECON mode 2 Allow the generator to run idle for approx 1 2 minutes 3 Set the engine switch to the OFF position 4 Turn the fuel valve to...

Page 9: ...CO2 inhalation of which can cause shock loss of consciousness and even death ATTENTION DANGER fill to here If the generator often operates at high temperature or high load the oil should be replaced...

Page 10: ...park plug spanner 6 Replace the spark plug cap The engine and muffler will be very hot after the engine has been run Avoid touching the engine and muffler while they are still hot with any part of you...

Page 11: ...ial faults and troubleshooting methods as well as average device capacities can be found in thefull version Potential faults and troubleshooting methods as well as average device capacities can be fou...

Page 12: ......

Page 13: ...sche Kundendienst technische Fragen und Unterst tzung Fragen und Unterst tzung support dimaxgroup de Garantie Reparatur und Garantie Reparatur und Service Service service dimaxgroup de Sonstiges Sonst...

Reviews: