K&S BASIC KSB 40i S Owner'S Manual Download Page 10

Spark plug is an importaint element providing the correct engine 

operation. It has to be intact, without soot deposits and to have a correct 

gap.

SPARK PLUG TECHNICAL MAINTENANCE

11

Electrode

0,6-0,7 mm

  

  

CLEANING THE FILTER:

CLEANING THE FILTER:

1. Open the clips on the upper cap of the air filter.

2. Remove the sponge filtering element.

3.  Remove all dirt deposits inside the hollow case of the air filter.

4.  Thoroughly wash the filtering element in warmsoapy water.

5. Dry the sponge filter.

6.  Dry filtering element is to be moistened by motor oil and excess oil is to be squeezed out.

Spark plug

  

  

SPARK PLUG INSPECTION:

SPARK PLUG INSPECTION:

1. Remove the cap from the spark plug.

2. Remove the spark plug by means of a corresponding spanner.
3.   Examine the spark plug. 

If it is shattered – it is necessary to replace it. Recommended replacement spark  

plugs – F7RTC. 

4. Measure the gap. It has to be within range 0.6 – 0.7 mm.

5. Place the spark plug in its place by means of a spark plug spanner.
6. Replace the spark plug cap.

The engine and muffler will be very hot after the engine has been run. Avoid touching the engine and muffler while 

they are still hot with any part of your body or clothing during inspection or repair.

MUFFLER SCREEN AND SPARK ARRESTER 

TECHNICAL MAINTENANCE

12

1. Remove the screws, and then pull outward on the areas of the cover.

2.  Loosen the bolt and remove the muffler cap, the muffler screen and spark arrester.

3.  Clean the carbon deposits on the muffler screen and spark arrester using a wire brush.

4. Check the muffler screen and spark arrester. Replace them if damaged.

5. Replace the flame arrester.

6. Replace the screen and cover of the damper.

7. Replace the cover and tighten the screws.

1. Remove the fuel tank cap and filter.

2. Clean the filter with gasoline.

3. Wipe the filter and install it.

4. Install the fuel tank cap.

Be sure the fuel tank cap is tightened securely.

FUEL TANK FILTER TECHNICAL MAINTENANCE

13

Tip: Align the spark arrester projection with the hole in the 

muffler pipe.

IMPORTANT!

Never use the gasoline while smoking or in the vicinity of an open 

flame.

ATTENTION - DANGER!

www.ks-power.de/en

   

|

    9

Summary of Contents for KSB 40i S

Page 1: ...Please read this manual carefully before use OWNER S MANUAL Inverter Generator KSB 40i S EN...

Page 2: ...he environment therefore we consider it expedient to savepaper and leave in print a short description of the most important sections leave in print a short description of the most important sections F...

Page 3: ...generator if you are tired under the influence of drugs or alcohol Inattention may cause a serious injury ATTENTION DANGER 1 Carrying handles 2 Fuel level indicator 3 Fuel tank cap 4 Fuel filter 5 Wh...

Page 4: ...e long service life of the generator continuous loads of more than 80 of the nominal power are not recommended Model KSB 40i S Voltage V 230 Max Power kW 3 9 Nominal Power kW 3 5 Frequency Hz 50 Curre...

Page 5: ...duce the load of the connected electric device below the specified rated output of the generator if the DC protector turns off If the DC protector turns off again stop using the device immediately and...

Page 6: ...controller settings in terms of the amount of fuel or speed governor this adjustment was made at the factory Otherwise this may result in changes in the engine operation or its failure IMPORTANT In th...

Page 7: ...NT Do not connect two or more devices at a time The start up of many devices requires high power Devices should be connected one at a time according to their power rating Do not connect any power cons...

Page 8: ...sconnect all devices connected to the generator then disable the ECON mode 2 Allow the generator to run idle for approx 1 2 minutes 3 Set the engine switch to the OFF position 4 Turn the fuel valve to...

Page 9: ...CO2 inhalation of which can cause shock loss of consciousness and even death ATTENTION DANGER fill to here If the generator often operates at high temperature or high load the oil should be replaced...

Page 10: ...park plug spanner 6 Replace the spark plug cap The engine and muffler will be very hot after the engine has been run Avoid touching the engine and muffler while they are still hot with any part of you...

Page 11: ...ial faults and troubleshooting methods as well as average device capacities can be found in thefull version Potential faults and troubleshooting methods as well as average device capacities can be fou...

Page 12: ......

Page 13: ...sche Kundendienst technische Fragen und Unterst tzung Fragen und Unterst tzung support dimaxgroup de Garantie Reparatur und Garantie Reparatur und Service Service service dimaxgroup de Sonstiges Sonst...

Reviews: