ACD200usermanual Fault Diagnosis and Countermeasures
- 20 -
C
CC
Code
ode
ode
ode
C
CC
Contents
ontents
ontents
ontents
C
CC
Code
ode
ode
ode
C
CC
Contents
ontents
ontents
ontents
Hd.00
Fault record for last time
Hd.06
Rated frequency when the fault
happened last time
Hd.01
Fault record for the last two times
Hd.07
Rated frequency when the fault
happened last time
Hd.02
Fault record for the last three
times
Hd.08
Rated frequency when the fault
happened last time
Hd.03
Fault record for the last four times
Hd.09
Rated frequency when the fault
happened last time
Hd.04
Fault record for the last five times
Hd.10
DC bus voltage when the fault
happened last time
Hd.05
Fault record for the last six times
3.3 Fault Reset
3.3 Fault Reset
3.3 Fault Reset
3.3 Fault Reset
When faults happens,you can choose anyone of the operation as follows to resume normal
operation:
(1)
Set any terminal of MI1、MI2、MI3 or MI6 to RESET Input (H6.00~H6.02=10,H6.03=10),
then disconnect after it closed with COM end.
(2)
When display the fault code, make sure that it can reset ,then press key .
(3)
Cut off the power.
(1) Before reset,must check the reason thoroughly and try to resolve,or it
will led to pomanent damage.
(2)If can not reset or fault happends again after reset,the user should check
for the reason,continuous reset will damage the inverter.
(3) When on overload and overheat protection,please reset after 5 minutes.
!