ACD200 Usermanual Functioanl Parameter List
- 12 -
H6.14
FDT1(frequency
level)level
0.00-upper limit frequency
0.1Hz 10.0Hz
○
8AH
H6.15
FDT1 lag
0.0-50.0Hz
0.1Hz
1.0Hz
○
8BH
H6.16
Analog output (AO1)
selection
0: output frequency (0-upper limit
frequency)
1: rated frequency (0-upper limit
frequency)
2:output current (0-2×rated current)
3: output voltage (0-1.2×load motor rated
voltage)
4: bus voltage (0-800V)
5: PID given value (0.00-10.00V)
6: PIDfeedback (0.00-10.00V)
1
0
○
8CH
H6.17 Analog output (AO1) gain 0.10-2.00
0.01
1.00
○
8DH
H6.18 Analog output (AO1) bias 0.00-10.00V
0.01
0.00
○
8EH
H6.24
Rated inner counter
value reaches given
value
0--9999
1
0
○
94H
H6.25
Specified inner counter
value reaches given
value
0---9999
1
0
○
95H
H6.26 Inner timer timing setting 0.1-6000.0s
0.1
60.0
○
96H
H7
H7
H7
H7-
--
- Specific Traverse Function Parameters
Specific Traverse Function Parameters
Specific Traverse Function Parameters
Specific Traverse Function Parameters
H7.00
Traverse function
selection
0: not use traverse function
1: use traverse function
1
0
×
97H
H7.01
Traverse operating
mode
LED units: throw-in mode
0: anto throw-in mode
1: manual terminal throw-in mode
LED tens:
0: variable swing range
1: fixed swing range
Notice: traverse central frequency input
channel is set by H0.00 functional
parameters
1
00
×
98H
H7.02
Traverse range 0.0-50.0(%)
0.1(%) 0.0(%)
○
99H
H7.03
Sudden jump
frequency
0.0-50.0(%)
0.1(%) 0.0(%)
○
9AH
H7.04
Traverse peroid
0.1-999.9s
0.1s
10.0s
○
9BH
H7.05
Triangular rising
time
0.0-98(%)(Traverse peroid)
0.1(%) 50.0(%)
○
9CH
H7.06
Traverse preset
frequency
0.0-400.0Hz
0.01Hz 0.00Hz
○
9DH