Operating Control Instruction
Master/Slave
Master
:
The master should set as built-in program and shows” P - X – X” send out
synchronization signals.
To avoid the host signal and DMX512 signals interfere
with each other, should cut off the DMX512 signals. The signal lines are longer
than 60 meters should increase a signal amplifier.
Slave
:
It must be in the SLAV mode and the address code should be A001 to assure
receive the master’s signals correctly. Only one light can be set as a Master and
others are slaves.
XLR cable connecting
XRL cable
:
:
:
:
The stand connection way of the XRL is: one end connects to the male plug, and
the other connects to the female.
Noted
:
In order to avoid failures and interference signal transmission
,
we connect
a resistance120Ω
(
1/4W
)
at the end of the DMX connecting as below: