K&F SONA 8 Operating Instructions Manual Download Page 14

Operating Instructions

K&F SONA 8

KLING & FREITAG GMBH © 2016

Version 1.4

Page 14 of 21

8.

Directions for the 100 volt connection.

KLING & FREITAG speakers with '100 V' option are fitted with high-quality transformers. This
serves to minimize loss of sound. Highly professional sound reinforcement results can be
achieved using '100 Volt' KLING & FREITAG speakers.

Reasons for choosing Speakers with 100 Volt Transformers:

Reduction in conduction loss.

Easy installation of a loudspeaker network due to simple parallel wiring. The sum of the
output power of the individual speakers (stated as VA = W) must not exceed the output
power of the 100 Volt amplifier.

Speakers are galvanically isolated.

Speakers can be integrated into existing 100 Volt systems.

9.

First-time Use

Switch off all equipment and turn down all level controls of the mixing console and the
power amplifiers.

Wire the SONA 8 systems.

Switch on the mixing console first, then the controller and the power amplifier. Always
use the before mentioned switching order. Otherwise switching noises may damage the
sound system.

If there is interference, turn off all appliances in the reverse order and check all cable
connections.

Successively turn up the individual power amplifier channels and send a signal with low
volume to the system. Check whether the audio is properly routed to the appropriate
speakers. Make sure no noise is heard through those speakers.
With controller: The SIGNAL LEDs of the CD 44 Controller will light up if the output
level is higher than -45 dB. Your system should now be ready for operation.

Turning down the input level controls may not always prevent distortions in the input
section of the power amplifier, especially if this section has a relatively low headroom.
A clipping signal may not be displayed by the clipping indicator then! To prevent signal
interruptions or damages to the speakers, turn the level controls of the power amplifier
to the maximum position, if possible. Set the output level of the mixing console or the
controller to a level that doesn't overload the power amplifiers or decrease the limiter
threshold of the controller.

When turning off the system, the input controls for the power amplifiers should be
turned down first followed by the power switches of the amplifiers. After that, the
other appliances can be turned off.

Summary of Contents for SONA 8

Page 1: ...ease Read Before Use KLING FREITAG GmbH Junkersstra e 14 D 30179 Hannover TEL 49 0 511 96 99 70 FAX 49 0 511 67 37 94 www kling freitag de Operating Instructions Translation of the original instructio...

Page 2: ......

Page 3: ...Safety 7 4 Wall and Ceiling Installation 8 4 1 Temporary alignment of the speakers 8 4 2 Outlet for Cable and Safety elements 8 4 3 Wall Mounting of the Speaker 10 5 Stand Installation 11 6 Proper Ali...

Page 4: ...p This icon marks information provided for simplified use of the described products 1 2 About these operating instructions KLING FREITAG GMBH All rights reserved All specifications regarding the featu...

Page 5: ...ball joint 4 Hexagon nut M10 17 mm spanner 5 Long nut hexagon M10 black version 16 mm spanner white version 17 mm spanner 6 Mounting plate with M10 bolt 7 Connection terminal cover with outlet for cab...

Page 6: ...before use If there are signs of wear cracks or deformation etc replace the affected parts immediately Visual inspection also includes checking all screwed connections of supporting components The inf...

Page 7: ...ers Alternately you can also insert a clipping limiter before the amplifier To protect the loudspeaker from mechanical damage when high SPL is required a highpassfilter of 24 dB oct at 60 Hz has to be...

Page 8: ...the three hexagon socket srews only This way you can avoid having to tighten an hexagon socket screw that got covered by the Mounting Arm while you aligned the speaker Loosen this screw s just enough...

Page 9: ...e safety eye in the speaker using the chain quick link Connect the speaker via the Speakon plug or the Phoenix connector First lay the safety element and then the speaker cable in the feedthrough slot...

Page 10: ...mounting plate you can also mount the Mounting Arm with other suitable 10 mm bolts Screw the mounting plate onto the wall or ceiling using all four mounting holes Choose fasteners that are suitable fo...

Page 11: ...ount a SONA 8 speaker on a stand you need the accessory Stand socket M10 1 For stand mounting you do not need the provided long nuts Unscrew them from the mounting arm and keep them for possible later...

Page 12: ...anding systems result in a greater difference in volume between front and back seats than higher standing systems To simulate the correct alignment of the speakers beforehand there are various program...

Page 13: ...e speakers at the amplifier is correct When simultaneously using power amplifiers from different manufacturers be sure to use the correct specific pin configuration It may be necessary to modify the p...

Page 14: ...system If there is interference turn off all appliances in the reverse order and check all cable connections Successively turn up the individual power amplifier channels and send a signal with low vo...

Page 15: ...al IEC 268 5 500 W program 1000 W Peak SPL 1 W 1 m 93 dB SPL Max SPL 1 m 124 dB SPL Components 8 low mid chassis 1 Hochtontreiber mit 45 mm Titanmembran CD Horn Impedance nominal 8 Ohm connectors behi...

Page 16: ...Operating Instructions K F SONA 8 KLING FREITAG GMBH 2016 Version 1 4 Page 16 of 21 11 Measuring Diagrams 11 1 Coverage SONA 8...

Page 17: ...Operating Instructions K F SONA 8 KLING FREITAG GMBH 2016 Version 1 4 Page 17 of 21 11 2 Frequency range SONA 8...

Page 18: ...12 Dimensions with Mounting Arm 250 6 mm 9 866 inch 120 mm 4 724 inch 461 6 mm 18 175 inch 29 440 6 mm 17 346 inch 285 3 mm 11 233 inch 102 1 mm 4 018 inch 140 mm 5 512 inch 5 mm 0 197 inch 450 5 mm...

Page 19: ...ossed out garbage can with a white bar below it The icon indicates that the equipment was distributed on or after 24 March 2006 and must not be disposed of through household waste KLING FREITAG GmbH i...

Page 20: ...SONA 6 SONA 8 SONA SUB SONS SUB II SW 112 SW 115D SW 115E SW 118E SW 212E These products are discontinued These systems are not covered by the Low Voltage Directive because of the rated voltage used W...

Page 21: ...Operating Instructions K F SONA 8 KLING FREITAG GMBH 2016 Version 1 4 Page 21 of 21 Managing Director CEO...

Reviews: