6.1
Installation to the Instrument Panel
1
O
Total pressure port – must be connected to the total pressure
tube.
2
O
Static pressure port – must be connected to the static pressure
tube.
3
O
Standard GPS antenna port – is used for external GPS antenna
needed by the GPS receiver integrated on AHRS unit.
4
O
Outside air temperature port – connects to the Kanardia OAT
digital probe.
5
O
Encoder port – connects with external encoder for regulating
QNH (optional).
6
O
RS-485 port – used to connect with devices via 485 protocol
such asindicators or LX Cluster.
7
O
Two CAN ports
– they are used to connect other CAN devices.
Connectors are equivalent so either one can be used to connect
a CAN device.
Emsis unit requires about 6 cm additional clearance behind. This
clearance is needed for the connectors and cables. Figure 29 shows
the photo of Emsis 80 mm version taken from side together with
all cables and connectors. Emsis 3.5” screen version requires similar
clearance space.
5
Emsis PFD is shipped with a connector inserted into one CAN port. It is a
120 Ω network terminator resistor to start and terminate the network. When
Daqu unit is connected, terminator can be disconnected.