Daqu — Manual
1.3
Technical Specifications
Daqu has two connectors on opposite sides. One is used to connect mani-
fold pressure hose and the other is used to connect CAN bus cable. Both
connectors require some additional clearence.
Four removable connectors on top are used to connect sensors. Some minimal
wire clearance is required, too.
Table 1:
Technical specifications for standard Daqu.
Description
Value
Weight
170
g
Size
125x80x20
mm
(LxWxH)
Operational voltage
7–32
V
Current (sensors not connected)
60
mA
at 12
V
Typical current (sensors connected)
100
mA
at 12
V
Operating temperature
–20
◦
C
to +85
◦
C
Humidity
30% to 90%, non condensing
Max current load of 5V power source
150
mA
(both sources together)
Max current load of 12V power source
150
mA
(both sources together)
Digital channels
3: (1xZ, 2xY)
Analog channels
22: (15xA, 2xB, 1xC, 2xD, 2xE)
Processor
Cortex M3, 60
MHz
Communication
CAN bus, Kanardia protocol
Connector
Binder 99 0414 00 05 (cable side)
9
©
Kanardia
2019