16
Kamstrup A/S • 5512603_C1_GB_03.2016
MULTICAL® 801
Auxiliary voltage from E+ and E- is
added to the passive contact output
P of the flow sensor before the signal
is connected to the galvanically
separated flow sensor input. This
permits a cable length of up to 100 m
between flow sensor and calculator.
KROHNE
ALTOFLUX
MULTICAL® 801
V1 (V2)
10B (69B)
11B (79B)
P
P
E+
E-
PE
The active pulse output of the flow
sensor is connected to the galvanically
separated flow sensor input directly.
This permits a cable length of up
to 100 m between flow sensor and
calculator.
BAILEY FISCHER & PORTER
COPA/MAG-XE
MULTICAL® 801
10B (69B)
11B (79B)
V1 (V2)
10
9
V3
V1
PE
PE
24V+
(V9)
(V8)
COPA/MAG-XM/CM
The passive contact output of the
flow sensor on terminals 56 and
57 is connected directly to the flow
sensor input which is not galvanically
separated. This permits a cable length
of max. 10-20 m between flow meter
and calculator.
MULTICAL® 801
SITRANS
57
56
11
9
10
Auxiliary voltage from terminals 97A
and 98A is added to the passive
contact output of the flow sensor
on terminals 56 and 57 before the
signal is connected to the galvanically
separated flow sensor input. This
permits a cable length of up to 100 m
between flow sensor and calculator.
MULTICAL® 801
SITRANS
57
56
10B
11B
97A
98A
Auxiliary voltage from terminals 97A
and 98A is added to the passive
contact output on terminals 24 and
25 before the signal is connected to
the galvanically separated flow sensor
input. This permits a cable length of
up to 100 m between flow sensor and
calculator.
MULTICAL® 801
E + H Promag
25
24
10B
11B
97A
98A