17
Kamstrup A/S • 55121600_A4_GB_03.2015
MULTICAL® 6M2
11 Setup via front keys
Date, time and primary M-Bus address can be adjusted by means of the front keys on the calcula-
tor’s front.
1 In the display you select the reading you want to change
2 Lift off the calculator top
3 Wait until the meter has shut down (up to 2.5 minutes). Do not press any keys
4 While remounting the calculator top, keep the main key activated
for approx. 8 seconds.
5 The setup menu is now active.
Having activated the setup menu the reading you want to
change is displayed with the rightmost digit flashing:
(in the below example, the ”Date” has been selected):
The value of the flashing digit can be changed by pressing the sub-key
.
The digit is increased by one each time the key is pressed, and passing 9 you start from 0:
When pressing the main-key
the next digit to the right will be flashing:
The active digit flashes and this digit can now be changed by pressing the sub-key
. It is possi-
ble to return to the first digit on the right by means of the main key
.
When the value of the reading has been changed you quit by pressing the main key
continu-
ously for approx. 10 seconds.
It should be checked whether the value is valid for the reading in question. If so, the value is saved
and an “OK” symbol is displayed. If not, the old value is maintained, no ”OK” symbol appears, and
the display reverts to legal reading.