7
Kamstrup A/S • 55121068_B3_GB_03.2015
MULTICAL® 62 • Water meter
4 Testing the function
Carry out a function control when the meter has been fully mounted. Press the button
on
MULTICAL® 62 and check that the displayed values for water low etc. are credible values.
5 Plug-in modules
A number of extra functions can be added to MULTICAL® 62 by means of plug-in modules. The
individual modules are briely described below.
5.1 Base modules
5.1.1
Data + pulse inputs, type 67-00-10
The data terminals are used for connection of
e.g. a PC. The signal is passive and galvanically
separated by means of optocouplers. Conver-
sion into RS232 level requires connection of
data cable 66-99-106 (D-Sub 9F) or 66-99-098
(USB) with the following connections:
62
Brown
(DAT)
63
White
(REQ)
64
Green
(GND)
The pulse inputs can be used for connection of
electricity and water meters.
Please note the maximum pulse frequency as
well as correct pulse coding (l/imp. and Wh/
imp.), which are selected by means of the FF
and GG conigurations.
65 - 66
Input A
67 - 68
Input B