2.1 Mounting the low sensor
Prior to
the installation of the low sensor the system ought to be lushed, a itting piece replacing
the meter.
Remove adhesive wafers/ protection membranes from the meter’s inlet and outlet and mount the
low sensor.
You must always use new gaskets in original quality.
The low direction is indicated by an arrow on the side of the low sensor.
Threaded meters are mounted by means of couplings. You must make sure that the threaded
lengths of the couplings do not prevent proper tightening of sealing surfaces and that PN10 cou-
plings are used (PN16 couplings/gaskets can be used).
Using strainer and/or nonreturn valve the enclosed thicker PE (polyethylene) gaskets
must
be used
in order to avoid damaging strainer or nonreturn valve.
Strainer, nonreturn valve and PE-gaskets must only be used in cold water meters.
PE-Gasket
Strainer
Nonreturn valve
PE-Gasket
FLOW
2.2 Installation angle for ULTRAFLOW® 24
ULTRAFLOW® 24 can be mounted vertically,
horizontally or at an angle.