Kamstrup MULTICAL 302 Installation And User Manual Download Page 6

6

Kamstrup A/S • 55121351_D2_GB_04.2015

MULTICAL® 302

4  Mounting of flow sensor

Prior to installation of the flow sensor, the 
system should be flushed and protection 
plugs/plastic diaphragms removed from the 
flow sensor.
Correct flow sensor position (inlet or outlet) 
appears from the display of MULTICAL® 302. 
The flow direction is indicated by an arrow on 
the side of the flow sensor.
The flow sensor may be used in both PN16 and 
PN25 installations and is available marked 
either PN16 or PN25 or marked both PN16 and 
PN25, as required.

A

A

SECTION A-A 

SCALE 2 : 1

Tightening by hand

O-ring

Gasket

12 mm

Enclosed couplings, if any, are only intended for PN16. Suitable PN25 couplings must be used in 
PN25 installations.
In connection with G¾x110 mm, it must be checked that 12 mm thread run-out is sufficient. See 
figure below.
Straight inlet: MULTICAL® 302 requires neither straight inlet nor straight outlet to meet the Mea-
suring Instruments Directive (MID) 2004/22/ EF and EN 1434:2007. A straight inlet section is only 
necessary in case of heavy flow disturbances before the meter. It is recommended to follow the 
guidelines of CEN CR 13582.

Recommended flow sensor position

Recommended flow sensor position

Unacceptable position due to risk of air 
build-up

Acceptable position in closed systems

A flow sensor should not be placed 
immediately after a valve, except for block 
valves, which must be fully open when not 
used for blocking

A flow sensor should not be placed close to 
the inlet side of a pump

A flow sensor should not be placed close to 
a two-level double bend.

A

B

C

D

E

F

G

In order to prevent cavitation, the operating pressure at MULTICAL® 302 must be min. 1 bar at q

p

 

and min. 2 bar at q

s

. This applies to temperatures up to approx. 80 °C.

MULTICAL® 302 must not be exposed to pressure lower than the ambient pressure (vacuum).

Summary of Contents for MULTICAL 302

Page 1: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg T 45 89 93 10 00 info kamstrup com kamstrup com Installation and User Guide MULTICAL 302...

Page 2: ...n with minimum vibration and fixed installation with considerable or high vibration level respectively Electromechanical environment E1 housing light industry The meter s signal cables must be drawn w...

Page 3: ...ting the function 11 8 Communication 11 8 1 Wired M Bus communication 11 8 2 Wireless M Bus communication radio 11 9 Setup Mode 12 9 1 Changing the installation position 13 9 2 Changing the energy uni...

Page 4: ...One temperature sensor is mounted in the flow sensor from the factory The other sensor ought to be mounted as direct sensor Alternatively both sensors must be mounted in sensor pockets as symmetrical...

Page 5: ...meter is configured for static info codes Info code Description Response time 0 No irregularities 1 Supply voltage has been interrupted 4 Temperature sensor T2 outside measuring range 32 secs 8 Tempe...

Page 6: ...ight inlet MULTICAL 302 requires neither straight inlet nor straight outlet to meet the Mea suring Instruments Directive MID 2004 22 EF and EN 1434 2007 A straight inlet section is only necessary in c...

Page 7: ...may be turned upwards to max 45 and downwards to max 90 compared to the pipe axis 4 5 4 5 9 0 9 0 4 5 4 5 9 0 9 0 Important The meter is most sensitive to air bubbles in the water when the plastic ca...

Page 8: ...e upper left corner of the meter display an icon indicates if the meter is positioned in the inlet or outlet pipe It is very important to ensure that the meter is correctly positioned as either inlet...

Page 9: ...broken In case of strong condensation e g cooling applications wall mounting of the calculator is recommended see paragraph 5 2 page 10 8 3 2 4 5 9 8 3 2 4 5 9 In connection with compact mounting the...

Page 10: ...flow sensor 6 Battery supply MULTICAL 302 is battery supplied with either 1 or 2 A cell batteries Optimal battery lifetime is obtained by keeping the battery temperature below 30 C e g by wall mountin...

Page 11: ...2 wire cable of 1 5 m The connection is independent of polarity and the M Bus interface is galvanically separated from the rest of the meter M Bus comes with primary secondary and enhanced secondary a...

Page 12: ...readings of Setup loop are listed below including index numbers Setup loop Loop_3 Index number in display 1 0 Customer number No 1 3 01 2 0 Customer number No 2 3 02 3 0 Date 3 03 4 0 Hour 3 04 5 0 Ta...

Page 13: ...ave the setting press the button for two seconds until OK appears in the display Outlet If the meter is set to be placed in the outlet the text Outlet is displayed In order to change the setting press...

Page 14: ...nd conversely the least significant digit disappears if e g you change from kWh with 1 decimal to kWh without decimals See examples below Example 1 GJ with 2 decimals B 2 This is an example of how the...

Page 15: ...or registers the amount of district heating water flowing through the heating system in m3 cubic metres The temperature sensors placed in inlet and outlet pipes register the cooling i e the difference...

Page 16: ...Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg T 45 89 93 10 00 info kamstrup com kamstrup com User Guide MULTICAL 302 Kamstrup A S 55121351_D2_GB_04 2015...

Reviews: