5.2 Wall mounting
The wall fitting makes it possible to mount
MULTICAL® 302 directly on an even wall. Use
the fitting as a template to mark and drill two 6
mm holes in the wall.
43
47
47
24
24
8
47
47
24
24
8
47
24
24
47
8
43
5.3 Position of calculator
If the flow sensor is mounted in a humid or
condensing environment, the calculator must
be placed in a higher position than the flow
sensor.
6 Battery supply
MULTICAL® 302 is battery-supplied with either 1 or 2 A-cell batteries. Optimal battery lifetime is
obtained by keeping the battery temperature below 30 °C, e.g. by wall mounting.
The voltage of a lithium battery is almost constant throughout the lifetime of the battery
(approx. 3.65 V). Therefore, it is not possible to determine the remaining capacity of the battery by
measuring the voltage. However, INFO code 128 indicates that the battery voltage is too low.
The battery cannot and must not be charged and must not be short-circuited. Used batteries must
be handed in for approved destruction, e.g. to Kamstrup A/S.