4

2  Connection

The IP module has no built-in encryption, and therefore it should always be 
placed behind a firewall or NAT (Network Address Translation).

3  Configuration

The IP201 module is always supplied configured with either default IP settings 
or custom IP settings. These settings can be changed subsequently by using  

IP Tool

, which can be obtained by contacting Kamstrup. 

It is possible to use either dynamic or static IP addresses, and it is possible to 
order with the following settings:

Dynamic IP address (DCHP):

Host server name 

(the DNS name or IP address of the server to which the unit 

must report back)

Static IP address:

IP address, subnet, gateway  

(network settings of the module).

Host server 

(the IP address of the server to which the device must report back)

.

4  Ethernet connection

The Ethernet connection on IP201consists of a standard 4-pole screw terminal.

Connection to switch, router or hub:

Terminal 

block No . on 

the PCB

T-568B Colour code

114

Green / White

115

Green

117

Orange

116

Orange / White

Summary of Contents for IP201

Page 1: ...Installation instructions IP201 English Kamstrup A S Industrivej 28 Stilling DK 8660 Skanderborg Tel 45 89 93 10 00 Fax 45 89 93 10 01 info kamstrup com www kamstrup com...

Page 2: ...on 4 3 Configuration 4 4 Ethernet connection 4 5 Installation 6 6 Localization of light emitting diodes extract of the module 7 7 Status LEDs 7 7 1 Action 7 7 2 Wink 7 7 3 Err 7 7 4 The service button...

Page 3: ...3 1 Mounting Typically the module is supplied mounted directly in RF Concentrator or similar equipment Example of mounting in RF Concentrator...

Page 4: ...her dynamic or static IP addresses and it is possible to order with the following settings Dynamic IP address DCHP Host server name the DNS name or IP address of the server to which the unit must repo...

Page 5: ...5 Connection to PC Terminal block No on the PCB T 568B Colour code 114 Orange White 115 Orange 117 Green 116 Green White Ethernet connection...

Page 6: ...tion to the network valid IP 3 The Err diode starts flashing when the host is recognised meter or concentrator have been detected 4 The Err diode turns off when the module has been registered by the c...

Page 7: ...raffic Steady light The module is connected but there is no traffic on the network 7 2 Wink The Wink diode is used for indicating the module s conditions in three situations Start up The Wink diode is...

Page 8: ...Kamstrup 3 wire connection that can be used for connecting additional external equipment For instance Connection of additional RF concentrator Port B is always configured for 9600 8 N 1 9 Module overv...

Reviews: