4
2 Connection
The IP module has no built-in encryption, and therefore it should always be
placed behind a firewall or NAT (Network Address Translation).
3 Configuration
The IP201 module is always supplied configured with either default IP settings
or custom IP settings. These settings can be changed subsequently by using
IP Tool
, which can be obtained by contacting Kamstrup.
It is possible to use either dynamic or static IP addresses, and it is possible to
order with the following settings:
Dynamic IP address (DCHP):
Host server name
(the DNS name or IP address of the server to which the unit
must report back)
.
Static IP address:
IP address, subnet, gateway
(network settings of the module).
Host server
(the IP address of the server to which the device must report back)
.
4 Ethernet connection
The Ethernet connection on IP201consists of a standard 4-pole screw terminal.
Connection to switch, router or hub:
Terminal
block No . on
the PCB
T-568B Colour code
114
Green / White
115
Green
117
Orange
116
Orange / White