2G/4G Network Module • HC-003-80

3  Connecting to READy Manager

When the CALL function in the meter has been activated, the meter will try to establish contact to the READy servers. If the 
call is successful, the Last seen time in READy for the module under Infrastructure, like in figure 1, now affects the time of 
the CALL. When the module sends data for the first time, READy automatically recognizes which meter is connected to which 
module.

4  Troubleshooting

If no OK appears in the meter display after the CALL function has been activated, you can see further information in the 
display. 

You can also test if the meter has been read via your mobile phone:

Open a browser, and enter https://check.kamstrup.com/.

Enter the serial number of the meter or the module.

Press the button “Test the connection”.

Display information

Menu index 49 can also be helpful in troubleshooting.

4.4.1  2-x01-4: Module status

Menu

Menu index

Information

Example of display reading

2-x01-4

49

Module status

Typical status codes during installation:

•  255 No connection attempted yet  
•   0 Transfer OK and all data sent  
•   1 Waiting for the network registration to complete  
•   2 Registration of network declined  
•   3 Waiting for a receipt from server  
•   4 Registration of network failed  
•   5 Missing antenna  
•   6 Connection error due to low voltage  
•   7 Data delivery timeout  

•  8 Data delivery timeout without an ACK
•  9 Could not connect  
•   10 Waiting for transfer  
•   11 DNS lookup error  
•   16 Flash write error  
•   32 Server error (possibly missing/wrong TEK)  
•   33 Waiting for connection  
•   34-35 Internal error  

If no connection can be established, please contact Kamstrup Support with the following information:

Meter serial no.

2G/4G or NB-IoT serial no.

Display index 47 and 49

Summary of Contents for HC-003-56

Page 1: ...Kamstrup A S 55123402_A1_EN_12 2022 NB IoT and 2G 4G modules HC 003 56 and HC 003 80 Installation Guide...

Page 2: ...K 8660 Skanderborg Denmark All rights reserved The graphics and content in this document are the copyrighted work of Kamstrup and contain proprietary trademarks and trade names of Kamstrup Third parti...

Page 3: ...3 2G 4G Network Module HC 003 80 Contents 1 Prerequisites 4 2 Mounting of meter and antenna 5 1 Mounting the module 5 2 The CALL function 6 3 Access to TECH loop 6 4 Access to connection information...

Page 4: ...several devices have been imported The date of the last reception of data is shown and if there is a problem with the device a red triangle appears For the marked module there has not been contact yet...

Page 5: ...ounted without sharp bends It is important that the antenna is mounted as high as possible and with large distance to other antennas and steel pipes to avoid noise and disturbances If the meter is mou...

Page 6: ...connection information If the second digit in display menu 47 is 1 or below you must move the antenna to a better location In some circumstances it may be necessary to extend the cables and to use an...

Page 7: ...e infrastructure 9 Connected to the NB IoT infrastructure The second digit indicates the connection quality 0 Very poor 1 Poor 2 Fair 3 Good 4 Excellent 1 Note that this information is a snapshot at o...

Page 8: ...l number of the meter or the module 3 Press the button Test the connection Display information Menu index 49 can also be helpful in troubleshooting 4 4 1 2 x01 4 Module status Menu Menu index Informat...

Reviews: